ETS 73
0548-990-51---60g_2019.10.indd
0548-990/52g
Page 88 of 98
Mounting and operating instructions
13.1.5
Menu level
Short and simultaneous actuation of both arrow keys (=access to the menu level).
Select the desired menu item bymeans of the arrow key.
Confirm by means of the OK key.
Display
Description
PARAMETER
Setting the motional parameters *
CONFIG
Setting the functionalities *
DOUBLE DOOR
Setting the closing sequence and interlock function *
DIAGNOSTICS
Diagnostic tool
ERROR ACTIVE
Active pending errors
ERROR HISTORY Formerly active errors
REINIT
Carry out a re-initialization *
BLOCK/UNBLOC Lock/unlock keys
TEACH
Initiate a setting-up procedure
make sure that the door leaf is completely closed.
* password protected
Note:
The detailed settings are described in chapter 7.4.