Place the unit in an upright position on a stable, flat surface.

Please ensure the unit is a safe distance away
from a wall or furniture (see diagram on the right).

Please keep clothes at a safe distance of
60 cm from air outlet of the unit to
prevent water dripping into the unit.

Where to position your dehumidifier?

For best results position the
dehumidifier somewhere central
like a landing or a hallway.
As long as the internal doors are open
the excess moisture from all of the rooms
in the house will migrate naturally towards
the dehumidifier and be processed.

Top
min 60cm

min 20cm

min 20cm

Air inlet

min 50cm

min 20cm

(When louvre up)

Air outlet

min 20cm

min 40cm

(When louvre closed)

 

Keep suitable space
as above

Ensure tank is fitted correctly,
if the tank is full or is not
in place, the "FULL" light will
stay on.

Do not remove tank when 
running, this will cause
water leaking.

Do not insert small
objects into the unit,
this will damage it and
cause a hazard.

The fragrance box can be 
released from the machine 
for refilling aromatic 
chemicals or scented 
materials. When using 
fragrance liquid, such as 
essential oil, please drip 
several drops into the sponge 
prepared in the box.
Never fill it too much to overflow.
Replace the fragrance box firmly in place 
to prevent access by infants.
Keep the fragrance box out of reach from small children.

6

Summary of Contents for DC204

Page 1: ...find many helpful hints on how to use and maintain your hybrid dehumidifier air purifier correctly Just a little preventative care can save you money and prolong the life of your unit Thank you for choosing DC204 ECOAIR TECHNICAL SUPPORT UK TEL 0845 388 0007 EMAIL technical ecoair org ECOAIR ...

Page 2: ...UCT DESCRIPTION THE CONTROL PANEL UNIT SETUP TO OPERATE SAFELY OPERATING INSTRUCTIONS TO EMPTY THE TANK TO DRAIN WATER Continuous Drainage MAINTENANCE TROUBLESHOOTING SPECIFICATIONS SILVER NANO FILTER ORDER FORM GUARANTEE CARD 1 2 3 4 5 6 6 7 8 9 9 10 11 12 13 14 15 ...

Page 3: ...er cord without press the ON OFF key to off first as this could damage the unit 12 Always unplug the unit when not in use or moving location To disconnect from the power supply grip the plug and pull from the power socket Never pull by the cord 13 Always empty the water tank before storing the unit away 14 Close supervision is necessary when any appliance is used by or near children and pets 15 Do...

Page 4: ...terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly If a 13A ...

Page 5: ...Movable and compact Dry Laundry and Purify modes to choose from Water level indicator enable easy checking of water level 3 Three running modes and water level indicator The unit has three louvre settings including a wide setting of 140 for drying laundry The rear air intake reclaims circulated air and makes for highly efficient drying 2 Highly efficient drying and dehumidifying The unit contains ...

Page 6: ...ank Control panel Hand grip to pull out the tank Handle Air inlet Air filter Silver Nano Filter and 3 in 1 Filter Water level indicator PRODUCT DESCRIPTION Fragrance box Continuous drain hole PRODUCT DESCRIPTION 4 ...

Page 7: ...ting DRY MODE key TIMER key Water Full indicator Indicator lights up when the tank is full of water or incorrectly installed Defrosting indicator Indicator lights up when the unit is defrosting Timer indicators Humidity indicators Louvre setting indicators Function indicators DC204 STATUS 5 ...

Page 8: ... processed Top min 60cm min 20cm min 20cm Air inlet min 50cm min 20cm When louvre up Air outlet min 20cm min 40cm When louvre closed Keep suitable space as above Ensure tank is fitted correctly if the tank is full or is not in place the FULL light will stay on Do not remove tank when running this will cause water leaking Do not insert small objects into the unit this will damage it and cause a haz...

Page 9: ...coal filter Before using 2 Automatic louvre adjustment swing The louvre automatically opens when switching on and closes when switching off Press SWING key to select range If SWING is off louvre can be manually adjusted 1 3 Tank must be properly fitted When Tank is full or not inserted Full water indicator light illuminates and unit will stop running Continuous draining is covered on the page 9 Wa...

Page 10: ...he unit is producing a large airflow for rapid drying eg for laundry dry with ionizer is on Dry the unit is producing a regular airflow for normal drying with Ionizer is on Up the louvre swings upwards to about 80 Front the louvre swings forwards to about 60 Wide the louvre swings in wide range to about 140 40 50 the unit stops dehumidifying automatically when humidity reaches 40 50 50 60 the unit...

Page 11: ...tom of the tank one hand on the left and lift carefully Turn off for 5 minutes before empty the tank NOTE Clean the tank with clean water if needed Do not use detergent solvent abrasive or hot water to avoid damage to the appliance Do not remove or damage the float in the tank the unit will not work correctly The FULL LED light will stay on until the tank is restore to the correct position Knockou...

Page 12: ... filter and the unit Cover the unit to prevent it from gathering dust 5 Store upright in a cool dry place Do not expose to direct sunlight How to Clean Cleaning the filter If the filter is covered with dust the airflow and the performance of the unit will be affected Check the filter periodically to ensure any dust is removed It is recommended to check and clean the air filter every 2 weeks or an ...

Page 13: ...t Is there any door or window open Is steam being generated in the room Is the room too big Try the laundry mode operation and let it run in this mode for a day Is the unit covered Is the unit positioned at the required minimum distances away from walls or objects See page 6 Unit Setup 1 If the unit fails to operate Is flashing Is the tank correctly installed Check and reposition Is the unit plugg...

Page 14: ...H Dehumidification Extraction Rate 14 1 litres day 26 7ºC 60 RH Water tank capacity 5 5 Litres Power Consumption 30ºC 80 RH 340W Power Consumption 26 7ºC 60 RH 300W Voltage 220 240V 50Hz Net Weight 12 Kg Gross Weight 13 5 Kg Net Dimension W x H x D 420mm x 600mm x 220mm Gross Dimension W x H x D 478mm x 667mm x 278mm 12 ...

Page 15: ...ay be changed without notification O R D E R F O R M O V E R L E A F 3 in 1 Filter Silver Nano Filter Tips For Cleaning Silver Nano Filter If the filter is covered with dust the airflow and the performance of the unit will be affected Check the filter periodically to ensure any dust is removed It is recommended to check and clean the air filter every 2 weeks or an appropriate frequency depending o...

Page 16: ...r Today By Fax Post Or Via Online Post Order Form Your Details Payment Details Please tick one below Company Name Name Address Post code Telephone Mobile Fax Email Model Number Description of Item Quantity Unit Price Amount Total Fax 0845 388 9313 Fax Form To Us ECOAIR Silver Nano Filter DC204 EcoAir Unit 7 Propeller Park 400 North Circular Road London NW10 0AB Tel 0845 388 0005 Mail Form To Us Mo...

Page 17: ... o ligaio s u de this gua a tee O ligaio s fo se i e a d pa ts u de this gua a tee ust e pe fo ed E oAi o a autho ised se i e o pa P odu t featu es o spe ii aio des i ed a e su je t to ha ge ithout oi e e oai o g C 77 TWO 2 YEAR LIMITED GUARANTEE SAVE THIS GUARANTEE INFORMATION E oAir gua a tees this p odu t f ee f o defe ts i ate ials a d o k a ship fo a pe iod of T o ea s f o the date of pu hase...

Page 18: ...Copyright Reserved WEE EC2601UR ...

Page 19: ...Copyright Reserved WEE EC2601UR ...

Page 20: ...Copyright Reserved WEE EC2601UR C177 ...

Reviews: