BS PLUG WIRING

 

Should it be necessary to change the plug, please note the wires in the mains lead are colour 

coded as follows:

 

 

BLUE 

-

 NEUTRAL

 

BROWN –

 

LIVE

 

GREEN AND YELLOW 

-

 EARTH

 

 

In the event that the colours of the wires in the mains lead of this appliance do not corre-

spond with the coloured markings identifying the terminals in your plug, proceed as follows:

 

 

1.

 

The BLUE wire is NEUTRAL and must be connected to the terminal which is marked 
with the letter N or coloured BLACK.

 

2.

 

The BROWN wire is LIVE and must be connected to the terminal which is marked with 
the letter L or coloured RED.

 

3.

 

The GREEN/YELLOW is EARTH and must be connected to the terminal which is marked 
with the letter E or         or coloured GREEN or GREEN/YELLOW.

 

4.

 

Always ensure that the cord grip is positioned and fastened correctly.

 

5.

 

If a 5A (BS 1363) fused plug is used it must be fitted with a 5A -fuse. 

 

If in doubt consult a qualified electrician.

 

 

Please note the Earth, Neutral and Live Terminals are marked as E , N and L respectively.

 

 

 

 

 

 

Summary of Contents for DD1 SIMPLE MK3

Page 1: ... 2022 EcoAir V1 4 DD1 Simple MK3 DESICCANT DEHUMIDIFIER USER MANUAL Please read instructions before use Keep for future reference Visit ecoair org to register your product or terms and conditions ...

Page 2: ...ruments and artwork by drying it out too much High humidity High humidity indoors causes damp and condensation The damp left by condensation can damage plaster wall paper furniture vehicles timber windows doors and clothes It can be harmful to our health when bacteria thrives causing mould and fungus Maintaining safe levels of humidity It is important to maintain a consistent humidity range to pre...

Page 3: ... 1 BS Plug Wiring 2 The Appliance and Accessories 3 Important Safeguards 4 Installation 5 Setup Continuous Drainage 6 Control Panel 7 Operation 8 Emptying the Water Tank 9 Cleaning Maintenance and Storing the appliance 10 Troubleshooting 11 12 INDEX ...

Page 4: ...ance before cleaning or maintenance or when not in use The appliance must not be placed or used where the atmosphere may contain combustible gasses oil or sulphur or solvent or near heat sources such as heaters or in server rooms or excessive dust Do not place or rest any objects on the appliance and do not cover while in use Always observe the minimum room size for storing and operating the appli...

Page 5: ...is NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN or GREEN YELLOW 4 Always ensure that the cord grip is positioned ...

Page 6: ...ONT BACK B1 DESCRIPTION Key Description Key Description A1 Control Panel B1 Continuous Drainage Hose A2 Louvre B2 User Manual A3 Air Outlet A4 Water Level Indicator A5 Handle A6 Water Tanks A7 Grip Handle A8 Filter A9 Air Inlet A10 Continuous Drainage Knockout A1 A4 A6 A7 A2 A3 A7 A1 A5 A6 A9 A8 A10 A4 ...

Page 7: ...nvironment where particles can clog up the filter or internal components DO NOT SPLASH Do not wash the appliance or immerse in water Do not allow water to drip on to the appliance IMPORTANT SAFEGUARDS WHERE TO POSITION YOUR DEHUMIDIFIER Ensure the unit is a safe distance away from a wall or furniture and away from direct sunlight TIP Position the dehumidifier in the dampest room or somewhere centr...

Page 8: ... Check that the dehumidifier is level to avoid any water leaks Turn on the dehumidifier to start dehumidification ZEOLITE When you first use the dehumidifier and periodically thereafter you may notice a smell coming from the dehumidifier This is caused by the Zeolite desiccant material and is NOT a sign that the dehumidifier is faulty nor is it harmful to humans or pets The Zeolite absorbs odours ...

Page 9: ...pen tap lead the other end of the hose to an appropriate drain at a downward slope with no sharp bends NOTE When using the dehumidifier with a continuous hose attached never pull out the tank This may cause water leakage or damage to the open tap If you need to re move the water tank ensure that the hose is disconnected first Never leave the end of continuous drainage hose outside when the tempera...

Page 10: ...ndicator lights up when the water tank is full or incorrectly installed 2 Power ON Indicator Indicates when the unit is ON 3 Humidistat Dial Select from POWER OFF LOW MEDIUM HIGH LAUNDRY CONTINUOUS MODE settings 4 Economy Turbo Switch Select TURBO or ECONOMY settings 1 2 3 4 DD1 Simple MK3 Black ...

Page 11: ...rt period of time Avoid using the laundry mode unattended ECONOMY TURBO MODES USING THE ECONOMY TURBO SWITCH Economy Select Economy mode for maximum energy saving and quiet operation Use this mode for normal daily use Highly recommended for night use Turbo Select Turbo mode for rapid dehumidifica tion For quick drying turn humidistat clock wise to the end and slide switch to TURBO Tip Once you rea...

Page 12: ...andle 6 Insert the water tank back into to the correct position The Water Full light indicator illumi nates if the water tank is not correctly in position If this happens reinsert again NOTE Clean the water tank with mild detergent if necessary Do not use solvent abrasive or hot water After Step 4 When cleaning the water tank take caution to avoid damaging the float Do not tilt the dehumidifier wh...

Page 13: ...ff and leave for 5 minutes then unplug the dehumidifier 2 Clean the surface with a soft damp cloth 3 Dry thoroughly with a towel after cleaning 4 For cleaning tank see Emptying the Water Tank section Caution Do not wash the unit or immerse in water Do not let water drip into the air inlet or outlet When cleaning the water tank take caution to avoid damaging the float STEP 2 REPLACING YOUR FILTER I...

Page 14: ... water tank Water tank or filter fitted incor rectly Check and refit the water tank or filter Check unit is on an even level surface Noisy Foreign object fallen through the vent into the dehumidifier Contact support ecoairgb com for AdHoc Service Dehumidifier placed on an une ven surface Place on an even surface If necessary test with a spirit level CHECK THE FOLLOWING POINTS BEFORE CONTACTING TEC...

Page 15: ...efore removing the tank Moving or tilting the dehumidifi er whilst water residue remains inside the dehumidifier Always turn off the dehumidifier wait 30 mins empty the tank and reinsert the tank before moving the dehumidifier Damaged water tank Remove the water tank fill with water and place on a hard even surface to test for leakage The continuous drainage is clogged or loose Check the continuou...