background image

INDEX

IMPORTANT INSTRUCTION ...................................................................................................

BS PLUG WIRING ...................................................................................................................

IMPORTANT SAFEGUARDS...................................................................................................

PRODUCT DESCRIPTION ......................................................................................................

THE CONTROL PANEL ...........................................................................................................

OPERATING INSTRUCTIONS ................................................................................................

CONTINUOUS DRAINAGE .....................................................................................................

MAINTENANCE ................................................................................................................

LONG TERM STORAGE........................................................................................................

SERVICE AND WARRANTY...................................................................................................

1

2

3

4

4

     5

     6

7 - 11

12

14

INSTALLATION AND MAINTENANCE OF HEALTHY FILTER.............................................. 13

BEFORE FIRST USE ............................................................................................................... 1

Summary of Contents for ECO DC10

Page 1: ...ntative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in the chart of troubleshooting tips Review the chart of Troubleshooting Tips before calling your service engineers keeping your home safe and clean ECOAIR TECHNICAL SUPPORT UK TEL 44 208 459 2458 EMAIL technical ecoair org ...

Page 2: ...MPORTANT SAFEGUARDS PRODUCT DESCRIPTION THE CONTROL PANEL OPERATING INSTRUCTIONS CONTINUOUS DRAINAGE MAINTENANCE LONG TERM STORAGE SERVICE AND WARRANTY 1 2 3 4 4 5 6 7 11 12 14 INSTALLATION AND MAINTENANCE OF HEALTHY FILTER 13 BEFORE FIRST USE 1 ...

Page 3: ...S BEFORE FIRST USE to keep it handy for future reference and the date you received the product together with your purchase receipt and attach to the warranty because it contains a compressor before use NOTE The rating of this product as marked on the product identification plate is based on specific Do not install and use your dehumidifier before completely reading these instruction up right posit...

Page 4: ...erminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or or coloured GREEN OR GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly If a 13A B...

Page 5: ...he unit is correctly connected before turning on the unit s power Never lay 9 To turn on your unit always use the switch on the control panel 10 Never unplug the dehumidifier while it is working This could damage the electronic circuits 11 Never place anything on top of the unit and do not cover it with any kind of cloth while it is plugged in or in use 12 Do not place objects on the product or al...

Page 6: ...efrostindicator THE CONTROL PANEL Operation indicator PRODUCT DESCRIPTION Continuous running mode Continuous Humidity control knob Air filter Bucket Air inlet Tube stopper Air outlet Power supply cord OFF Switch off Handle CONTINUOUS ...

Page 7: ...fully before switching the unit on again Full Bucket Lamp Do not use the extension cord or the same socket with other electric appliance working life the compressor will not start until the unit has run for 3 minutes Remove the water in the water RUNNING DEFROST FULL While turning on or off the machine the defrost lamp would be bright once The unit will shut down when turned to OFF position or whe...

Page 8: ... DRAINAGE permanent drainage When using continuous drainage the PVC hose must be placed at a downward slope below the drainage hole Avoid uneven surfaces and do not kink the hose Not Supplied Take out the continuous drainage tube stopper from the drainage pipe outlet 3 Take out the bung from the drainange pipe Hose stopper Bung ...

Page 9: ...d every two weeks and more often if the machine operates in a dusty atmosphere The build up of dust reduces the efficiency of the dehumidifier Therefore the air filters must be warm water never use hot or soapy water Make sure that the air filters are completely If the filters are obstructed the dehumidifier will be less efficient Clean the filters with a vacuum cleaner If the filters are very dir...

Page 10: ...it can not be started in case operation Discard the water in the drainage The Running lamp disconnected the outlet tank and then reposition the tank above36 Cor below 5 C The protection device is actuated and the case please do not use the dehumidifier is under the bad environment in that loose or mulfunctioning The unit does not Is the Red lamp blinking The tank is full or in a wrong position Che...

Page 11: ...contact EcoAir Tel 44 208 459 2458 or if outside the UK your retailer if the problem continues Do not try to repair it by yourself as this could cause an electrical shock Clean the air filter as instructed obstructed No air is discharged function does not work under Caring for the dehumidifier Is air intake port or discharge port Remove whatever is obstructing the Is the air filter clogged Use the...

Page 12: ...st used the discharged Very little dehumidifying takes place The humidity does not drop during use or none takes place air smells musty room is sufficiently low an unusual or musty odour may occur The following symptoms do not indicate a breakdown 1 The humidity setting is incorrect 2 The room not warm 3 The filter clogged with dust 4 The unit too close to wall or any object 5 Is the room size too...

Page 13: ... mode is changed an unusual noise is heard room it may echo stabilizes The fan is running and the compressor When the unit is first powered up or after a defrosting operation it will take 3 minutes before the compressor begins operation This is a protection device to protect the compressor and prolong its life does not work Water Leaking 1 Room Temp low 2 The unit was moved while it was turned on ...

Page 14: ...ommend that you take the following steps Remove water from the water bucket If continuous drainage hose is connected disconnect it Disconnect the unit and wrap the power cord and plug Clean the unit and store it protecting it from dust Store the unit in an upright position Keep it in a cool dry place and away from sunshine ...

Page 15: ...ealthy filter into the groove for filter and button up As shown in right figure b Air filter b Installation Instruction 3 Put the filter back into the dehumidifier Clean and Maintenance Remove the healthy filter before cleaning and reinstall after cleaning according to the installation Changing your filter The filter will last for one year under normal usage condition We recomended changing the fi...

Page 16: ...to service or modify the unit will render this WARRANTY VOID The actual product may differ slightly from illustration This warranty is in addition to and does not affect your statutory rights For further information please contact 020 8459 2458 This product has been manufactured to comply with the EC Directives 2006 95 EC and 2004 108 EC SERVICE AND WARRANTY ONE 1 YEAR LIMITED WARRANTY Save This W...

Reviews: