background image

Summary of Contents for ECO2OLDF

Page 1: ...s on how to use and maintain your dehumidifier properly Just a little preventative care on your part can save you a great deal of time and money over the life of your dehumidifier You ll find many answers to common problems in the chart of troubleshooting tips Review the chart of Troubleshooting Tips before calling your service engineer ...

Page 2: ...ance as unsorted waste or with your domestic household waste Please observe local regulations for disposal Most local authorities have specific collection systems for appliances where disposals are free of charge to the end user When replacing an existing appliance with a new appliance your retailer may take back the old appliance for disposal ...

Page 3: ...nal which is marked with the letter N or coloured BLACK The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter Eor or coloured GREEN OR GREEN YELLOW Always ensure that the cord grip is positioned and fastened correctly If a I 3A BS 1363 fus...

Page 4: ...panel and features 4 Otherfeatures 5 IDENTIFICATION OF PARTS Identificationof parts 5 OPERATING THE UNIT Positioning the unit using the unit 6 Emptyingthe water tank 7 CARE AND MAINTENANCE Care and cleaning the dehumidifier 8 Optional Filter Hepa Carbon Filter 9 TROUBLESHOOTING TIPS Troubleshootingtips 10 0 L P ...

Page 5: ...uh1t I_ 1 plugIaIqI r IIL k Q1 a heat source It may cause electric shock or S It may cause electric shock Plastic parts may melt and fire due to heat generation cause a fire It may cause fire and electric It may cause failure of machine It may cause electrical shock shock or electric shock or injury Do not use the machine near I Do not drink or use the Do flammable gas or combustibles such water d...

Page 6: ... The manufacture s nameplate is located on the rear panel of the unit and contains electrical and other technical data specific to this unit The dehumidifier must be properly earthed To minimize shock and fire hazards proper earthing is important The power cord is equipped with a three pin plug for protection against shock hazards Your dehumidifier must be used in a properly grounded wall receptac...

Page 7: ...d and quiet operation is preferred set the fan control to LOW Note The continuous mode will operate until the bucket is full if drained to bucket Humidit Setting Press or19to select the desired humidity setting o Display Shows the set humidity level while setting then shows the actual 5 accuracy room humidity level Error Codes El Humidity sensor error Unplug the unit and plug it back in If error r...

Page 8: ... power failure water full or when the desired humidity level is reached This is a safety 1 The bucket is full or when the bucket is removed measure designed to protect the unit 2 When the bucket is removed or not replaced in the proper position 3 When the setting humidity is reached Auto Defrost When frost builds up on the evaporator coils the compressor will switch off but the fan will continue t...

Page 9: ...ted in an enclosed area to be most effective Close all doors windows and other outside openings to the room 40cm or more Air outlet grille Air intake grille 20cm 20cm or more d i 20cm or more 20cm or more Fig 4 Castors At four points on the bottom of unit Castors can only move laterally Do not force castors to move over carpet nor move the unit with water in the bucket The unit may tip over and sp...

Page 10: ... re start when the bucket is restored in its correct position NOTES When you remove the bucket do not touch any parts inside of the unit This may damage the product Be sure to push the bucket gently all the way into the unit securely otherwise it may cause damage to the unit Avoid Spillage Fig 6 Do not place the bucket on the floor as the bottom of 3 Pour the water out the bucket is uneven Bucket ...

Page 11: ...e bucket must be in place and securely seated for the dehumidifier to operate 3 clean the air filter The washable nylon air filter Fig lOc behind the front grille should be checked and cleaned at least every 30 days or more often if necessary NOTE THE FILTER IS NOT DISHWASHER SAFE To remove Grip the tab on the filter and pull it upward then pull it out as shown in Fig 10a Clean the filter with war...

Page 12: ... on frequency of usage You may replace it with a Carbon Filter instead Replacement HEPAor Carbon Filter can be purchased directly from EcoAir Please contact 020 8459 2458 The HEPAor Carbon Filter is optional but the washable nylon filter must always be used To replace the HEPA or Carbon filter First remove the washable nylon air filter Fig 11 a Remove the HEPA filter from the frame behind the air ...

Page 13: ...ity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 F There is a kerosene heater or something giving off water vapor in the room CThe unit makes a loud 1 The air filter is clogged The unit is tilted instead of upright as it should be noise when operating 1111111 0 The floor surface is not level Frost app...

Page 14: ...commended at voltages indicated on the unit Any attempts made to service or modify the unit will render this WARRANTY VOID The actual product may differ slightly from the illustration This warranty is in addition to and does not affect your statutory rights For further information please contact 020 8459 2458 This product has been manufactured to comply with the EEC Directives 73 23 EEC and 89 336...

Reviews: