background image

3-Year Limited Warranty

ecobee warrants that for a period of three (3) years from the date of purchase by the consumer (“Customer”), 
the ecobee Power Extender Kit (the“Product”) shall be free of defects in materials and workmanship under 
normal use and service. During the warranty period, ecobee shall, at its option, repair or replace any defective 
products, at no charge. Any replacement and/or repaired device are warranted for the remainder of the 
original warranty or ninety (90) days, whichever is longer. 
If the product is defective, contact the supplier from whom the product was purchased to obtain an 
equivalent replacement product, provided the supplier determines that the returned Product is defective and 
the Customer is otherwise eligible to receive a replacement product; 
This warranty does not cover removal or reinstallation costs and shall not apply if the damages were found to 
be caused by something other than defects in materials or workmanship, including without limitation, if the 
product: 

•  was operated/stored in abnormal use or maintenance conditions; 

•  is repaired, modified or altered, unless ecobee expressly authorizes such repair, modification or 

alteration in writing; 

•  was subject to abuse, neglect, electrical fault, improper handling, accident or acts of nature; 

•  was installed improperly. 

ecobee’s sole responsibility shall be to repair or replace the Product within the terms stated above. ECOBEE 
SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY SPECIAL, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, 
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some US states and Canadian provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation 
or exclusion may not apply to you. ecobee’s responsibility for malfunctions and defects in materials and 
workmanship is limited to repair and replacement as set forth in this warranty statement. All express and 
implied warranties for the product, including but not limited to any implied warranties and conditions of 
merchantability and fitness for a particular purpose, are limited to the three-year duration of this limited 
warranty. No warranties, whether express or implied, will apply after the limited warranty period has expired. 
Some US states and Canadian provinces do not allow limitations on how long an implied warranty lasts, so 
this limitation may not apply. ecobee neither assumes responsibility for nor authorizes any other person 
purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty 
or liability concerning this product. This warranty gives you specific rights, and you may also have other rights 
which vary from jurisdiction to jurisdiction. If you have any questions regarding this warranty, please write 
ecobee Customer Service, 477 Richmond St West 2nd Floor, Toronto ON M5V 3E7, Canada or contact customer 
service at 1-877-932-6233 or email at support@ecobee.com.

EB-PEK-01 

ecobee® is a registered trade-mark of ecobee, inc. © 2013 ecobee, inc. All rights reserved.

Product Specifications

Environmental 

For indoor use only 
Temperature: -40°F to 160°F (-40°C to 70°C)
Humidity:  5-95% RH (non-condensing)

Dimensions

3.3 x 2.0 x 1.0 inches (84 x 52 x 26 mm)

Electrical

Input: 18 to 30 VAC (50 or 60 Hz), 30mA@24V 
Output: 18 to 30 VAC (50 or 60 Hz)  2A per terminal

Need Help?

Contact us at:
Toll free 1.877.932.6233 

support@ecobee.com 

www.ecobee.com

477 Richmond Street West | 2nd Floor.
Toronto, Ontario , Canada   M5V 3E7

Step 3. Connect the Wires

The next step is to connect the wires between the thermostat, diode, wiring 
harness, and HVAC equipment.

1.  Connect the C wire coming from the thermostat to the C terminal on the 

STAT side of the wiring harness. You can repurpose the wire that would 
have been connected to W on a 4-wire thermostat.

2.  Connect the RC/RH and G wires from the thermostat to the RC/RH and G 

terminals on the STAT side of the wiring harness.

3.  Connect the output from the diode to the Y terminal on the STAT side 

of the wiring harness. You can re-use the wire that would have been 
connected to Y on a 4-wire thermostat.

4.  Connect the RC/RH, G (fan), Y, C, and W wires on the EQUIP side of the 

wiring harness to the matching terminals on your air hander.  

Y N/C

W

O/B

G

RC

RH

C

Y2

W2

AUX

Air Handler

W

Y

Diode

Existing 4 wires 

(in wall)

G

C

W

Y

RH RC

G

C

W

Y

RH RC

ST

AT

EQUI

P

 Thermostat Backplate

Wiring Harness

G

C

W

Y

R

New wire

RC, RH, G (fan), Y & W 

connect as usual.
C is a new wire that needs 

to be added since there

is no common wire.

RC, RH, & G (fan) connect 

as usual
Y is the only wire used for Y & W
C is the repurposed wire 

(wire taken from W)

Diode connects to Y & W
Diode output connects 

to Y on wiring harness

C (existing wire 

taken from W) 

Terminals 

for 5-wire

thermostat

Step 4. Power On the System

After you have completed the wiring, you can power on and test the system.

1. Re-attach the thermostat to the backplate. Ensure that the pins on the 

thermostat align with the terminal block on the backplate.

2.  Power on the HVAC equipment. The thermostat should automatically 

power on.

3.  Test your wiring by alternately adjusting the set temperature and running 

the different heat, cool, and fan modes.

4.  Once you are satisfied the wiring is correct, re-attach the wiring harness’s 

front cover. Make sure the wires exit the module via the wire channel.

5.  Re-attach any cover panels that you previously removed on the HVAC 

equipment 