background image

14

Note:

 If the inclusion was not successful completed the 

LED is flashing separately red and green.

Note: 

During the inclusion/exclusion phase, the device 

should be within 1 meter of MyVirtuoso Home gateway.

Operation

If the inclusion operation was successful:

• 

Switch ON: red LED.

• 

Switch OFF: green LED.

LED meaning depending on energy load:

• 

~ 3 AMP: green LED.

•  3 ~ 7 AMP: orange LED.

•  7 ~ 10 AMP: red LED.

When  overload  state  occurs  (the  load  is  more  than 

10.5A) the module is automatically disabled, overload 

state can be cleared by unplugging and reconnecting 

the module from the wall socket.

Manually  turn  the  connected  appliance  On/Off  by 

pressing the On/Off button.

Summary of Contents for Socket switch and power meter

Page 1: ...1 Manuale di istruzioni www ecodhome com Presa attuatrice e di misura...

Page 2: ...2 Sommario 3 Introduzione 4 Descrizione e specifiche prodotto 5 Installazione 6 Funzionamento 7 Smaltimento 7 Garanzia...

Page 3: ...ianti Il presente modulo un dispositivo certificato Z Wave compatibile con i gateway della linea MyVirtuoso Home La presa attuatrice e di misura essendo alimentata dal la rete elettrica svolge anche l...

Page 4: ...ollegata La presa attuatrice svolge anche la funzione di ripeti tore di segnale Il presente dispositivo stato studiato per un utilizzo interno Specifiche Protocollo Z Wave Frequenza di trasmissione 86...

Page 5: ...ante di inclusione del dispositivo 3 volte con secutivamente entro 1 5 sec Per l esclusione posizionare il gateway MyVirtuo so Home in modalit esclusione quindi premere il pulsante di inclusione del d...

Page 6: ...de 3 7 AMP LED arancione 7 10 AMP LED rosso Quando si verifica un sovraccarico carico superiore a 10 5A il dispositivo viene automaticamente disabilita to e la presa entra in modalit protezione Il sov...

Page 7: ...ngono smaltiti in discari che o nei posti non appropriati le sostanze pericolose possono fuoriuscire nelle acque sotterranee ed entra re nella catena alimentare danneggiando la salute e il benessere Q...

Page 8: ...8 SmartDHOME Srl www ecodhome com info smartdhome com P N 01335 1450 00 Rev 09 2016...

Page 9: ...9 www ecodhome com Socket switch and power meter Installation Manual...

Page 10: ...10 Summary 11 Introduction 12 Product description and specification 13 Installation 14 Operation 15 Warning 15 Limited warranty...

Page 11: ...with the home automation gateway This module is a Z Wave enabled device and is ful ly compatible with MyVirtuoso Home network Every mains powered Z Wave enabled de vice acts as a signal repeater and m...

Page 12: ...l switch This plug in on off module is able to detect cur rent wattage and overload wattage of connect ed appliances This module also acts as repeater For indoor use only Specification Protocol Z Wave...

Page 13: ...ndi cator which is used to carry out the inclusion or exclusion 2 For Inclusion Put MyVirtuoso Home gateway into inclusion mode and press the inclusion button of the device 3 times within 1 5 seconds...

Page 14: ...clusion operation was successful Switch ON red LED Switch OFF green LED LED meaning depending on energy load 0 3 AMP green LED 3 7 AMP orange LED 7 10 AMP red LED When overload state occurs the load i...

Page 15: ...le If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the ground water damaging the environment and human health When replacing old appliances with new o...

Page 16: ...16 SmartDHOME Srl www ecodhome com info smartdhome com For United Kingdom and Ireland only refer to www ecodhome co uk info smartdhome co uk P N 01335 1450 00 Rev 08 2016...

Reviews: