PRE-CALIBRATION MAX GAS 500

-

1

,

0

 

0

,

0

 

1

,

0

 

2

,

0

 

3

,

0

 

4

,

0

 

5

,

0

 

6

,

0

 

7

,

0

 

8

,

0

 

50

 

100

 

150

 

200

 

250

 

300

 

350

 

400

 

450

 

500

 

550

 

600

 

 

pressione

 

ca

m

era

 

di

 

co

m

b

u

stione

 m

bar

 

k

W

 

11

,

5

 

12

 

12

,

5

 

13

 

14

 

15

 

16

 

1

 

2

 

3

 

5

 

4

 

posizione

 

testa

 

pressione

 

gas

 

in

 

testa

 m

bar

 

EXAMPLE OF PRE-CALIBRATION MAX GAS 500

Warning: 

the pre-calibration values have been

determined on EN676 test combustion cham-
bers in ideal conditions, and are useful for the
first switch-on but must be checked and correc-
ted with calibration for the individual system.

Example in figure

:

Power required by the generator: 380 kW.
Pressure envisaged in combustion chamber: 3.5
mbar. Combustion head chamber: 2.5  (between
2 and 3). Gas pressure in head: 13 mbar.

Gas pressure in head

Head position

ADJUSTING THE AIR PRESSURE SWITCH

The air pressure switch must be adjusted so that an insufficient air flow does not allow

the CO value to exceed 1%  in volume. After having adjusted the gas flow and obtained

optimum combustion (CO

2

= 9.5 to 9.8% and a CO value of less than 75 ppm), the air

pressure  switch  must  be  adjusted.  Remove  the  cover  with  the  burner  operating,  cover

the air intake progressively with a piece of cardboard to obtain a value of CO

2

= 10.8

(G20-G25)> 13 (G31) and a CO value of less than 5,000 ppm. Adjust the air pressure

switch until the burner shuts down. Remove the cardboard from the air intake and start

up the burner again. Replace the cover.

ADJUSTING THE GAS PRESSURE SWITCH

Adjust the pressure switch to 50% of the rated pressure of the gas used.
RARED PRESSURE: 

G 20 = 20 mbar   G 25 = 25 mbar
G 31 = 37 mbar

0,4

0,6

0,9

3,0

1,

5

2,1

1,

8

2,4

2,7

1,2

A

B

2,5

5

10

15

50

25

35

30

40

45

20

C

D

Pr

es

su

re

 in

 c

om

b.

 c

ha

m

be

r

Gas pressure in head

Head position

Pr

es

su

re

 in

 c

om

b.

 c

ha

m

be

r

EN

420010318203  

Max Gas 350 - 500 P/P AB 

22

Summary of Contents for MAX GAS 350 P AB

Page 1: ...X GAS 350 P AB MAX GAS 500 P MAX GAS 500 P AB Low Nox 420010318203 02 08 2011 BRUCIATORI DI GAS AD ARIA SOFFIATA BLOWN AIR GAS BURNERS BRULEURS GAZ A AIR SOUFFLE QUEMADORES DE GAS DE AIRE SOPLADO IT E...

Page 2: ...er and regulations Working of the burner p 17 Control box up cycle p 18 Adjusting air gas p 19 PAB minimal gas adjustment p 20 Air servomotor adjustment p 20 Regulating the combustion p 21 22 Adjustin...

Page 3: ...200 200 100 300 400 300 400 500 600 0 1 2 3 4 5 6 7 8 9 mbar kW kcal h x 1000 MAX GAS 350 P AB MAX GAS 500 P AB 500 WORKING FIELDS Output Backpressure in comb chamber OPERATING FEATURES Model Max Gas...

Page 4: ...o control that this last is perfectly sealed Also verify that the chimney is not obstructed Open the gas cock and carefully bleed the piping through the pressure gauge connector then check the pressur...

Page 5: ...d off disconnect the flame detection cable from relevant electrode so as to make the valve to automatically shut off at the ignition after the safety time Make a reading on the gas meter Start the bur...

Page 6: ...lays KL Low fire LK Air damper LKP Air damper position LP Air pressure switch LR Load controller M Fan motor R Control thermostat pressurestat SA Actuator STB Safety limit thermostat Si External pre f...

Page 7: ...stment of burner no fuel Faulty ignition equipment 3 blinks on LP faulty Loss of air pressure signal after t10 LP welded in normal position 4 blinks on Extraneous light when burner is started up 5 bli...

Page 8: ...for air damper position on burner s shutdown total close 0 II Adjusting cam ORANGE for opening position in ignition and Low Flame by the screwdriver III Adjusting cam RED for opening position in High...

Page 9: ...ng the combustion head figure to suit the power required as shown in figure 3 dose the gas by regulating the gas ramp see figure in the ramp manual Low flame setting 1 after regulating the maximum pow...

Page 10: ...in head 13 mbar Gas pressure in head Head position ADJUSTING THE AIR PRESSURE SWITCH The air pressure switch must be adjusted so that an insufficient air flow does not allow the CO value to exceed 1...

Page 11: ...C microammeter with a 0 50 or 0 100 A dial When the burner is run ning and is properly adjusted the value read must be steady and never be smaller than 1 5 A LME 11 21 22 LANDIS LME11 LME21 22 min 1 5...

Page 12: ...13 14 15 16 7 7 7 8 9 10 11 12 EN 420010318203 Max Gas 350 500 P P AB 24...

Page 13: ...urner connected That the gas pressure is correct and the gas cock open That the control systems are correctly connected If all these conditions are present start the burner by pressing the release but...

Page 14: ...ING SWITCH INTERRUTTORE DI LINEA ER ELETTRODO DI RIVELAZIONE IONISATION PROBE ELECTRODE D IONISATION ELECTRODO DE IONIZACION ELETTROVALVOLA GAS GAS SOLENOID VALVE ELECTROVANNE GAZ ELECTROVALVULA DE GA...

Page 15: ...XTRA SAFETY GAS SOLENOID VALVE ELETTROVALVOLA GAS DI SICUREZZA ELECTROVANNE GAZ DE SECURITE SAFETY THERMOSTAT THERMOSTAT DE SECURITE TERMOSTATO DE SEGURIDAD TERMOSTATO DI SICUREZZA TERMOSTATO CALDERA...

Page 16: ...ri SERVOMOTOR FLAME SENSOR S p A ECN FIRST CREATION BY TERM LAWS WE RESERVED THE PROPERTY OF THIS WIRING DIAGRAM WITH PROHIBITION OF USE AND REPRODUCTION LEAKAGE CONTROL CONTROL BOX DATE ECN MODICATIO...

Page 17: ...PRESSION MIN GAS PRESSURE SWITCH MIN PRESSOSTATO GAS DI MINIMA SAL FUSIBILE FUSE FILTRE ANTIPARASITES MAIN SWITCH WITH FUSE ANTJAMMING FILTER FILTRO ANTIDISTURBO FILTRO DE PROTECION ANTIDISTURBIO INTE...

Page 18: ...flam Bruciatori SERVOMOTOR FLAME SENSOR S p A ECN FIRST CREATION BY TERM LAWS WE RESERVED THE PROPERTY OF THIS WIRING DIAGRAM WITH PROHIBITION OF USE AND REPRODUCTION LEAKAGE CONTROL CONTROL BOX DATE...

Page 19: ...MMING FILTER FILTRO ANTIDISTURBO FILTRO DE PROTECION ANTIDISTURBIO INTERRUPTOR GENERAL CON FUSIBLE INTERRUPTEUR GENERAL AVEC FUSIBLE INTERRUTTORE GENERALE CON FUSIBILE STC SPA STS FUSIBLE FUSIBLE MOTO...

Page 20: ...0 1 1 2 3 4 5 6 7 8 9 10 17 16 11 12 13 15 14 18 19 20 22 21 MAX GAS 350 P MAX GAS 500 P 23 24 25 27 28 26 29 30 31 32 33 34 35 36 350 P RU ES FR EN IT 420010318203 Max Gas 350 500 P P AB 68...

Page 21: ...1 I II 1 2 3 4 5 6 7 8 9 10 17 16 11 12 13 15 14 18 19 20 22 MAX GAS 350 P AB MAX GAS 500 P AB 25 350 P 21 23 24 27 28 26 29 30 31 32 33 34 35 36 37 RU ES FR EN IT 420010318203 Max Gas 350 500 P P AB...

Page 22: ...DE PRESSION SOPORTE ACCESO DE PRESI N 65324691 65324691 21 CABLE D IONISATION CABLE DE IONIZACION TC 65320946 65320946 TL 65320947 65320947 22 CABLE D ALLUMAGE CABLE DE ENCENDIDO TC 65320944 65320944...

Page 23: ...20 95 4 65324691 65324691 21 9 4 U 5 TC 65320946 65320946 TL 65320947 65320947 22 9 04 1 TC 65320944 65320944 TL 65324194 65324194 23 5 4 U 5 65320950 65320950 24 5 04 1 65324331 65324331 25 1 5 9 2 1...

Reviews: