pag.42

B

LB972  

MULTICALOR 300.1-400.1 PR/AB 

TC = SHORT HEAD   TL = LONG HEAD

Multicalor 300.1 

Multicalor 400.1

N° DESCRIPTION

code

code

1 - AIR PRESSURE SWITCH

DUNGS LGW10 A2P

Q120

Q120

2 - WIELAND PLUG

6 pin

E226

E226

3 - AIR INTAKE SET 

GRPA100

GRPA100

4  - COVER

BFC09254/038

5 -  GLASS

BFC02004

BFC02004

6 - PEED WINDOM FRAME

BFC02006

BFC02006

7 -  MOTOR

5,5 k W

M128/017

-

7,5 k W

-

M129/017

8 - FAN

320 x 150

BFV10304/001

BFV10304/001

9 - AIR CONVEYOR

BFC08256/001

BFC08256/001

10 -  AIR INTAKE

GRCA320

GRCA320

11 - AIR INTAKE PIPE

BFS02208/201

BFS02208/201

12 - CONTROL BOX BASE

LANDIS

A401

A401

13 - CONTROL BOX

LANDIS LFL1.622

A113

A113

LANDIS LFL1.333

A124

A124

14 - IGNITION TRANSFORMER 

BRAHMA T8

T101

T101

15 - REMOTE CONTROL SWITCH

BF25.00

R617

-

BF40.00

-

R616

BG0910A

-

R623

16 - REMOTE CONTROL SWITCH (PUMP)

MC9.10

R603/1

R603/1

17 - MOTOR THERMAL RELAY

Lovato RF25 9-15A

R513

-

Lovato RF25 14-23A

-

R513/1 

18 - MOTOR THERMAL RELAY (PUMP)

Lovato RF9 2-3,3 A

R510/1

R510/1

19 - MAIN SWITCH

cod.40100I1509

R1020

R1020

20 - GAS/LIGHT-OIL SELECTOR

R1020/5

R1020/5

21 - SELECTOR

R1020/5

R1020/5

22 - LAMP

Elettrospring EL/N-SC4

E1510

E1510

23 - FUSE SUPPORT

FUSIT FH-B528

E802/2

E802/2

24 - RELÉ BASE

Finder 5532

R905

R905

Finder 5534

R906

R906

25 - RELÉ 

Finder 5532

R711

R711

Finder 5534

R712

R712

26 - UV CELL

LANDIS QRA 2

A205

A205

27 - IGNITION CABLE

TC

BFE01403/2

BFE01403/2

TL

BFE01403/3

BFE01403/3

28 - IGNITION ELECTRODES SET

E612

E612

29 - PIPE

TC

BFT14031/001

BFT14031/001

TL

BFT14032/001

BFT14032/001

30 - ROD

TC

BFA08020/101

BFA08020/101

TL

BFA08020/201

BFA08020/201

31 - FIRING HEAD

BFT14033/001

BFT14033/001

32 - FRONT DISC

BFD07042

BFD07042

33 - NOZZLE HOLDER

BLT02057

BLT02057

34 - INNER ASSEMBLY

TC

TL

35 - BLAST TUBE 

TC

BFB07023/103

BFB07026/103

TL

BFB07023/203

BFB07026/203

36 -  GASKET  ISOMART

BFG04051/1

BFG04051/1

37 -  ANTIJAMMING FILTER

S132/4

S132/4

38 - AIR DAMPER MOTOR

LANDIS SQM50.481A2

M212/91

M212/91

39 -  SILENCER

GRSIL04/01

GRSIL04/01

40 - OIL PUMP

SUNTEC TA3C40105

P148/1

P148/1

41 - COUPLING

MP501/4

MP501/4

42 - PUMP MOTOR

740 W

M147

M147

43 - OIL  VALVE

SIRAI L159C3

V407

V407

44 - COIL

SIRAI L159C3

V507

V507

45 - OIL  VALVE

SIRAI L159C3

V407

V407

46 - COIL

SIRAI L159C3

V507

V507

47 - OIL FILTER

70501/03

S107/5

S107/5

48 - HOSES

TN 18X1500

S902

S902

49 - MANOMETER

CEWAL R1/4 D50-40BAR

S601/1

S601/1

50 - PILOT GAS VALVE

BRAHMA EG12SR

V142/1

V142/1

51 - COIL

BRAHMA EG12SR

52 - NOZZLE

FLUIDICS W2 kg/h 225-50

U802/14

-

FLUIDICS W2 kg/h 250-50

U802/15

53 - FAN SCOOP

-

BFC08059/001

54 - MODULATING UNIT

LANDIS RWF 40

E1215

E1215

Summary of Contents for Multicalor 300.1 PR

Page 1: ...LB1448 20 07 2005 Multicalor 300 1 PR MD Multicalor 400 1 PR MD Light oil Natural gas 40 300 mbar Light oil LPG 75 300 mbar MODELS A BRUCIATORI MISTI GAS GASOLIO B GAS LIGHT OIL DUAL BURNERS...

Page 2: ...atural Gas L C V 8 570 kcal Nm3 LPG L C V 22 260 kcal Nm3 Light oil L C V 10 200 kcal kg max visc 1 5 E at 20 C OVERALL DIMENSIONS Burner output Backpressure in combustion chamber I M L E D D1 F C B A...

Page 3: ...the air servocontrol in approximately 30 seconds time When the servocontrol is fully open a signal to the electronic control unit starts the 66 seconds pre purge cycle At the end of the prepurging tim...

Page 4: ...ation probe which cuts in and sets the burner shutdown within the safety time In case of gas lack or a major pressure drop the minimum air pressure switch shuts down the burner Ref Description t1 Dura...

Page 5: ...STING THE MAXIMUM CAPACITY OF THE GAS Position the selector situated on the control panel on position 1 and proceed as follows Adjusting the maximum gas flow rate see figure on solenoid valve adjustme...

Page 6: ...p cover M ADJUSTMENT OF THE AIR PRESSURE SWITCH Unscrew screws A and B and remove cover C Set the pressure switch to the mini mum by turning regulator D to position 1 Start the burner and keep in low...

Page 7: ...st be suitable for burner The connection of boiler s thermostats and all the safeties The motor rotation direction The correct calibration of the motor s thermal protection When all the above mentione...

Page 8: ...button on the control box If after a successful pump priming the burner locks out after the prepurging due to a fuel pressure drop in the pump rearm the burner s lock out to restart the burner Do neve...

Page 9: ...p 5 Selector 0 Loking of devoices for operating at intermediate outputs Operation at max output Operation at min output AUTO Automatic operation 6 Main switch I O 7 Selector 0 Light oil Gas 8 Lockout...

Page 10: ...ses are blown out The control box is faulty THE BURNER RUNS THE PREPURGING AND SWITCHES TO LOCKOUT AT THE END OF CYCLE Check the fan and the air pressure Check the air pressure switch Control box faul...

Page 11: ...LOSE 1st Stage Increase power OPEN 2nd Stage Two stage operation Description of display and keys on the RWF 40 microprocessor regulator The figure shows the normal display indicating the actual value...

Page 12: ...to access the parameters level To move from one parameter to the next press PGM PGM When HYS1 is displayed burner ignition differential stage II increase or decrease the value using the and keys Conf...

Page 13: ...1 Connection for probe QAE2 passive probe Water probe Configuration code C111 9XXX Connection for probe FT TP passive probe Degusa probe Configuration code C111 5XXX Connection for probe QBE620 P act...

Page 14: ...faulty the regulator will not indicate the real value Situation The number 1999 blinks in the display as the actual value with SP E showing in the set point field Cause The external set point value i...

Page 15: ...e relative opening in the electrical panel A Insert the fixing anchors and screws into the slots and secure the unit to the panel B To open the regulator squeeze the cover from the ends as shown and l...

Page 16: ...ive probe QBE620 P QAE22 FT TP 1000 P4 P10 P16 P25 P40 Analog input 1 2 and 3 setpoint changeover shift C111 9030 5030 G000 G000 G000 G000 G000 Limit comparator controller type setpoint 1 locking C112...

Page 17: ...A UV 19 03 1998 Q N BEM43167 3 MULTICALOR 300 1 400 1 500 1 PR PR LANDIS SQM 50 481A2 LANDIS LFL 1 622 VPS 504 UV 11 03 2005 FMP 95 96 KMV R S T NO FMV MV U V W FMP MP U V W S R T KMP R S T NO SAMA 1...

Page 18: ...TV MV MP KA FU Z Q SWITCH OIL GAS COMMUTATORE GASOLIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS THERMOSTAT GRANDE PETIRE ALLURE HIGH LOW FLAME THERMOSTAT TERMOSTATO DI ALTA BASSA FIAMMA COMM...

Page 19: ...2005 FMP 95 96 KMP R S T NO KMV R S T NO MP U V W MV U V W Q HLB FMV FMP S R 10 11 8 5 6 7 9 T N FMV 95 96 SAgG 1 2 3 0 SAMA 1 2 3 0 FMV 97 98 HLBT GAS 2 GASOLIO 1 COMMUTATORE ALTA BASSA FIAMMA SWITC...

Page 20: ...LIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS TERMOSTATO DE SEGURIDAD COMMUTATORE MANUALE AUTOMATICO SWITCH MANUAL AUTOMATIC INTERRUPTEUR MANUEL AUTOMATIQUE CONMUTADOR MANUAL AUTOMATICO THERM...

Page 21: ...1 33 LFL 1 622 VPS 504 UV 22 06 2005 FMP 95 96 KMV R S T NO FMV MV U V W FMP MP U V W S R T KMP R S T NO SAMA 1 2 3 0 HLBT FMV 97 98 SAgG 1 2 3 0 GAS 2 GASOLIO 1 T P STC 50 Hz 400V HLB STAB T P STS R...

Page 22: ...MP KA FU Z Q SWITCH OIL GAS COMMUTATORE GASOLIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS THERMOSTAT GRANDE PETIRE ALLURE HIGH LOW FLAME THERMOSTAT TERMOSTATO DI ALTA BASSA FIAMMA COMMUTATOR...

Page 23: ...6 Q N BEM43188 1 MULTICALOR 300 1 400 1 500 1 PR PR LANDIS SQM 50 481A2 LANDIS LFL 1 333 LFL 1 622 PREDISPOSTO UV 03 11 2005 FMP 95 96 KMV R S T NO FMV MV U V W FMP MP U V W S R T KMP R S T NO SAMA 1...

Page 24: ...TATORE GASOLIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS THERMOSTAT GRANDE PETIRE ALLURE HIGH LOW FLAME THERMOSTAT TERMOSTATO DI ALTA BASSA FIAMMA COMMUTATORE MANUALE AUTOMATICO SWITCH MANUAL...

Page 25: ...400 1 PR AB Multicalor 300 1 PR MD Multicalor 400 1 PR MD 7 8 36 11 14 4 6 5 3 9 10 39 26 31 29 30 27 34 32 33 52 35 28 2 37 20 13 12 25 24 22 23 19 21 17 16 15 18 1 41 50 51 44 43 47 53 38 49 42 46 4...

Page 26: ...802 2 24 REL BASE Finder 5532 R905 R905 Finder 5534 R906 R906 25 REL Finder 5532 R711 R711 Finder 5534 R712 R712 26 UV CELL LANDIS QRA 2 A205 A205 27 IGNITION CABLE TC BFE01403 2 BFE01403 2 TL BFE0140...

Page 27: ...right to make without any prior notice all those modifications which it deems usefull and or necessary in order to improve the quality of its products without affecting their main features CEcoflam S...

Reviews: