14
7. Recommended spare parts
Technical Data
Booster/Main station.
Advanced*
Proff.**
Water
Unit.
3 (4 kW)
3 (4 kW)
4 (5.5 kW)
7 (10 kW)**
8 (11 kW)*
Max. Outlet pressure.
bar
25
25
25
22
25
Consumption during rinsing. 1)
L/min
90
90
120
210
240
Consumption during foaming.
L/min
30
30
40
80
80
Min. supply pressure.
bar
2
2
2
2
2
Max. supply pressure.
bar
8
8
8
8
8
Min. water supply.
L/min
100
100
135
265
265
Max. water temp.
°C
70
70
70
70
70
Pipe dimension inlet Ø
inch
1.1/4"
1.1/4"
1.1/4"
2"
2"
Pipe dimension outlet Ø
inch
1.1/4"
1.1/4"
1.1/4"
2"
2"
Electricity
Supply voltage
V
3/PE 400 V ±10%
Frequency
Hz
50/60 Hz 48 0%…62 +0%
Motor load (kW)
kW
4
4
5.5
10
10
Installation to EN 60204-1
Nominal current
A
10.6
10,6
14.2
27
27
Fuse
A
16
16
20
35
35
L1, L2, L3, PE
mm2
2.5
2.5
2.5
6
6
General
Sound level ISO 11202
dB
Below 70
Below 70
Below 70
Below 70
Below 70
Dimensions
mm
1070 x 550 x 375
785 x 550 x 375
1074 x 557 x 382
1074 x 557 x 382
990x535x364
Weight (kg)
kg
85
60
75
75
80
All specifications are based on 5 bar supply pressure
Note:
* Pump pressure 20 bar + inlet pressure max. 25 bar
** Pump pressure 20 bar + inlet pressure max. 22 bar
1) 1 user per 30l/min.
8. Specifications
The recommended spare parts are marked with * in the spare part manual.