The Airspexx unit must be placed
on a firm, plain and horizontal
surface. For DS2 place unit on
specfied height in relation to jer-
rycan.
Put the suction lance in a 20L can
with Airspexx disinfectant. Always
be aware that the suction lance
touches the bottom of the can.
Connect compressed air.
Connect mains voltage.
To start up the Airspexx push the
green button. After a few seconds
the unit starts up (depending on
settings).
Select the required program
(different times can be set under
the program menu).
Make sure that the spray picture is
as required.
6. Operation
7. Maintenance
The Airspexx unit is maintenance
free.
However, it might be necessary to
clean the nozzle.
If the nozzle is blocked try hold-
ing a finger infront of the nozzle
outlet (always use gloves in case
of chemical in the nozzle). Com-
pressed air will unblock the nozzle
by rinsing the dosing line with air.
After release (take out finger from
outlet) the nozzle should operate
like intended.
DO NOT TRY TO ADJUST THE
NOZZLE!
Adjustment of nozzle is only al-
lowed by authorised personnel.
Safety instructions
Only authorized customer service provider or qualified
personnel shall undertake to execute maintenance
work. They have to be familiar with all applicable safety
regulations.
Always disconnect from power supply before opening
machine.
10
Summary of Contents for DS1-RMT
Page 1: ...Airspexx Dispensing System DS1 RMT DS1 SST DS2 DS2 HH Directions for Use 110002976 EN...
Page 13: ...1082 110003394A 13...
Page 18: ...18 11 Safety Technical Data Sheet...
Page 19: ...19...
Page 20: ...20...
Page 21: ...21...
Page 24: ...24...
Page 25: ...Spare part...
Page 26: ...26 13 12 1 11 11 12 12 12 9 3 4 2 7 5 10 4 8 4 6 16 14 15 110002793E...