background image

Important instructions for operators/users/installers

Introduction:

This nozzle is developed according to up-to-date technology and meets the current national and international safety 

requirements. The nozzle has a high degree of operating safety as a result of our company’s long development 

experience and constant quality control.

By normal operation, the nozzle is safe.

Nonetheless, some potential sources of danger to people, material and optimal operation remain, especially when daily 

routine and technical faults coincide.

This operating manual therefore contains basic safety instructions, which must be observed when configuring, operating, 

fitting and removing the nozzle. They must be read by the operator/user/installer before commissioning, fitting or removing 

of the nozzle and must be available to the above-mentioned persons at all times.

General safety requirements:

The following rules must always be observed:

• 

 The nozzles must only be used as intended. Changes to the operating conditions must be clarified with the manufac-

turer.

•   Usage as intended includes observation of the various instructions in this safety technical data sheet and in the 

   operating and installation manual as well as observation of all trade association instructions.

•   The operating personnel must be made familiar with the function and handling of the nozzle.

• 

 Installation, configuration, commissioning, fitting or removal must only be carried out by qualified personnel.

• 

 The nozzle must only be operated by qualified/authorised users.

•   Adaptations and changes of the nozzle must only be carried out by authorised personnel in consultation with the 

manufacturer. All liability lapses in case of adaptations or changes carried out by other persons or adaptations or 

changes not agreed with the manufacturer.

Before any commissioning, the following must be carried out/observed:

•   Function test

•   Check that all nozzle connections are placed securely and tightly

•   Working safety 

The nozzles are exposed to the following kinds of wear:

•   chemical

•   thermal

•   mechanical

The nozzles must therefore regularly be tested and replaced as necessary. The nozzles must only be operated in 

technically faultless condition. 

•   Never point the liquid jet/spray at people or electrical equipment. There is a risk of injury by the addition of chemicals,  

   high temperatures or pressures, solids or electrical current. WARNING: With media such as gas, air or steam, the jet  

   is barely visible.

•   There is a danger of inhalation of the jet. Especially by atomisation of chemicals or other materials representing a  

   danger to health, remedial action must be taken with appropriate measures 

   (e.g. suction, suitable breathing protection). 

• 

 The work area must be spacious and marked with appropriate warning symbols.

•   During the spraying, the nozzle assumes the temperature of the medium/media being sprayed. 

• 

 There is a danger of burning or freezing – remedial action must be taken with suitable protective clothing.

•   If materials representing a danger to health are sprayed, suitable protective clothing must be worn when fitting or  

   removing the nozzle. 

The nozzle must only be adjusted, fitted or removed with appropriate tools. WARNING: When adjusting, fitting or removing 

the nozzle, all hoses must be unpressurised and empty.

 Connections must be cleaned before fitting.

Any warranty lapses if the nozzle is used incorrectly or with the wrong materials.

 

22

Summary of Contents for DS1-RMT

Page 1: ...Airspexx Dispensing System DS1 RMT DS1 SST DS2 DS2 HH Directions for Use 110002976 EN...

Page 2: ...r supply 9 6 Operation 10 7 Maintenance 10 8 Trouble shooting 11 9 Specifications 12 10 Electrical Connections 14 11 Safety Technical Data sheet 14 Spare part 21 EN Wear safety glasses Wear gloves War...

Page 3: ...st mmelse Vaatimustenmukaisuusvakuutus Overensstemmelseserkl ring Deklaracja zgodno ci Megfelel s gi nyilatkozat Izjava o skladnosti Izjava o uskla enosti Deklaracija o konformitetu Declara ie de Conf...

Page 4: ...2009 og EN 61000 3 3 2008 D claration de conformit Nous Nilfisk ALTO d clarons sous notre propre responsabilit que les produits Airspexx auxquels se r f re cette d claration sont conformes ces direct...

Page 5: ...geheel onder eigen verantwoordelijkheid dat de producten Airspexx waarop deze verklaring betrekking heeft in overeenstemming zijn met de volgende Richtlijnen van de Raad betreffende de onderlinge aanp...

Page 6: ...atkozat vonatkozik megfelelnek az EU tag llamok t rv nyi rendelkez seinek k zel t s r l sz l tan csi ir nyelveknek Funkci Air Hygiene Station Modell T pus DS1 RMT DS1 SST DS2 DS2 HH Sorozatsz m sszes...

Page 7: ...e e produkty Airspexx na kter se toto prohl en vztahuje vyhovuj po adavk m n sleduj c ch sm rnic rady v r mci harmonizace se z kony lensk ch st t EU Funkce Air Hygiene Station Model Typ DS1 RMT DS1 SS...

Page 8: ...2009 Elektromagnetinio suderinamumo direktyv 2004 108 EB 2004 12 15 taikytas standartas EN 55014 1 A1 2009 ir EN 55014 2 A2 2008 taikytas standartas EN 61000 3 2 A2 2009 ir EN 61000 3 3 2008 Atbilst...

Page 9: ...nit is 200 ml hour using 2 bar air pressure The intended use is with this standard setting Adjustment of nozzle is only allowed by authorised personnel The controller consists of a display for setting...

Page 10: ...Operation 7 Maintenance The Airspexx unit is maintenance free However it might be necessary to clean the nozzle If the nozzle is blocked try hold ing a finger infront of the nozzle outlet always use g...

Page 11: ...move freely up and down Call a service technician No chemistry comes out of the nozzle Make sure chemistry can is full Check if pressurized air connected Check if you can hear the relay activate when...

Page 12: ...3 Bar Air consumption 40 l min 40 l min 40 l min 40 l min Drop size 10 m 10 m 10 m 10 m Max surroundings temp 40 C 40 C 40 C 40 C Weight 23 0 kg without chemical can 17 0 kg without chemical can 8 0 k...

Page 13: ...1082 110003394A 13...

Page 14: ...active if set enable OUT1 Error signal Low level only if set enable Empty can always active OUT2 Not used XJ1 Air valve XJ4 Product lance Low level and Empty can XJ10 Display See software manual for c...

Page 15: ...on C Init san 1 DCC EFS Next page 2 No of pages 2 Page Dwg Number 110003013 Dato 13 02 2017 Project responsible SAN L L N N PE PE max 10Vdc max load 230Vac 100mA PCB V6B or Higher max load 40Vdc 250mA...

Page 16: ...ite unit for Airspexx DS1 and DS2 Airspexx Revision C Init sab 2 DCC EFS Next page No of pages 2 Page Dwg Number 110003013 Dato 13 02 2017 Project responsible SAN Display K4 Q1 Lance K3 W1 XJ1 XJ2 XJ4...

Page 17: ...9 A B C D E F A B C D E F Airspexx DS unit Pneuamtic Airspexx Pneumatic Revision B Init 1 DCC EFS Next page No of pages 1 Page Dwg Number 110003378 Dato 04 10 2013 Project responsible SAN G1 K1 K3 Lan...

Page 18: ...18 11 Safety Technical Data Sheet...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Page 22: ...thorised personnel in consultation with the manufacturer All liability lapses in case of adaptations or changes carried out by other persons or adaptations or changes not agreed with the manufacturer...

Page 23: ...on depending on the usage purpose When the air cap is turned anti clockwise the propellant throughput is reduced and the jet stream becomes more pointed When the air cap is turned clockwise the propel...

Page 24: ...24...

Page 25: ...Spare part...

Page 26: ...26 13 12 1 11 11 12 12 12 9 3 4 2 7 5 10 4 8 4 6 16 14 15 110002793E...

Page 27: ...02709 Sauglanze Lance d aspiration 1 1 1 1 Lanza de aspiraci n Sugelanse Operation panel 7 110002790 Bedienungspaneel Panneau d op ration 1 1 1 1 Panel de la operaci n Betjeningspanel Label kit 8 1100...

Page 28: ...l no 118 01 000XXX 2013 All rights reserved ECOLAB Engineering GmbH F B Engineering Competence Centre EMEA Raiffeisenstra e 7 D 83313 Siegsdorf Telephone 49 86 62 61 0 Fax 49 86 62 61 2 35 e Mail engi...

Reviews: