417101438_EMPII_E60.docx
- 98 -
Rev. 11-02.14
9.7
Delivery condition
9.7.1
Basic setting of the mode of operation / display in the operating display
On delivery, the mode of operation internal is displayed in the version “display/ strokes”.
Therefore, the following parameters are shown on the display when the main voltage is
switched on.
Operating mode:
internal
Metering frequency / - quantity:
strokes / min (122 strokes / min at 50 Hz,
146 H strokes / min at 60 Hz)
Operating state:
OFF (at V 4.1, „Standby“ at V4.0)
(to start the pump press START / STOP key)
Fig. 9.8
Basic setting of the mode of operation / display in the operating display
NOTE
With each stroke of the pump, the indicator in the upper right of the display
rotates 1 turn.
9.7.2
Basic settings in the configuration
The following factory settings are defined in the configuration.
Fig. 9.9
Basic settings in the configuration
Configuration of
Standard
see Chapter
language:
German
unit:
litre
code:
not active (-)
auto start:
not active (-)
metering lock:
not active (-)
low level contact:
open (
)
alarm output:
off (
)
pulse memory:
not active (-)
oval gear meter:
not active (-)
metering controler:
not active (-)
meter monitor:
not active (-)
microflow :
not active (-)
batch:
not active (-)
degas:
not active (-)
microflow
Only appears on the display in conjunction with the
MicroFlow
PLUS
metering monitor, which is available as an
accessory.