OPERATION MANUAL

EcoloxTech 240 System

EcoloxTech

Tel. +1 954-900-6070

 

service@ecoloxtech.com

Last Update: May 1, 2020

Summary of Contents for 240

Page 1: ...OPERATION MANUAL EcoloxTech 240 System EcoloxTech Tel 1 954 900 6070 service ecoloxtech com Last Update May 1 2020 ...

Page 2: ...tons and Display Page 4 Operational Modes Page 4 Settings Performance Page 5 System Alarms Page 5 Safety Precautions Page 6 Additive Formulas Page 6 Changing Additive Page 7 Controlling Concentration Page 7 Measuring Concentration Page 10 Routine Maintenance Page 10 ...

Page 3: ...free available chlorine FAC Ampere Settings 13 to 22 amp Pump Speed Settings 0 to 19 max speed to min speed Ambient Temperature 5 to 50 C 41 to 122 F Feed Water Brine Temperature 10 to 30 C 50 to 86 F Inflow Water Brine Water Quality Hardness less than 80 ppm required Hardness over 80 ppm will damage electrolysis cells Humidity Less than 96 Relative Humidity RH Minimum Flow Rate 1 L min Maximum Wa...

Page 4: ...Setting to standard mode 1 Press and hold Set button for 3 seconds and release 2 Press Reset button once 3 Press and hold Mode button for 3 seconds and release Level Mode This mode must be used when connecting the system to a holding tank using a float sensor The system will automatically stop running when the water level rises to the level to activate the float sensor Setting to level mode 1 Pres...

Page 5: ...an adjustable setting The range is from 0 to 19 Lower settings will increase the pump speed and thus increase the additive dosed into the electrolysis cell For most purposes the pump speed should be kept in mid range Adjusting the pump speed 1 Press and hold Set button for 3 seconds and release LED display will begin to blink 2 Press Mode button until pump speed PS setting is displayed 3 Press Set...

Page 6: ...stem inflow water the pH of the HOCl solution will be improved pH below 7 BETTER 70 of FAC is HOCl Formulation 28 Food Grade Salt NaCl 72 Water tap water reverse osmosis or distilled When preparing 2 Liter additive tank 1 Add 550 g 2 cups of salt 2 Fill remainder with water 1400 mL 3 Shake until salt fully dissolved No iodine or other additives ie kosher salt 2 Using Formula 2 the system will gene...

Page 7: ...ange the concentration 1 Flow Rate L min controlled by blue valve allowing feed water to flow into system 2 Ampere A controlled by system settings 3 Pump Speed PS controlled by system settings 17 5 A 22 0 A 111 ppm 131 ppm 116 ppm 136 ppm 120 ppm 142 ppm 125 ppm 147 ppm 131 ppm 153 ppm 136 ppm 160 ppm 17 5 A 22 0 A 10 PS 83 ppm 98 ppm 8 PS 87 ppm 102 ppm 6 PS 90 ppm 106 ppm 4 PS 94 ppm 111 ppm 2 P...

Page 8: ...g Additive Formula 2 Distilled White Vinegar and Food Grade Salt Flow Rate 2 0 3 0 L min Using Additive Formula 2 Distilled White Vinegar and Food Grade Salt Flow Rate 3 5 5 0 L min 10 PS 8 PS 6 PS 4 PS 2 PS 0 PS pH Raise pH Lower pH Pump Speed PS 10 PS 8 PS 6 PS 4 PS 2 PS 0 PS pH Raise pH Lower pH Pump Speed PS 10 PS 8 PS 6 PS 4 PS 2 PS 0 PS pH Raise pH Lower pH Pump Speed PS 10 PS 8 PS 6 PS 4 PS...

Page 9: ... Rate 1 0 1 5 L min Using Additive Formula 3 Water Food Grade Salt and HCl Flow Rate 2 0 3 0 L min Using Additive Formula 3 Water Food Grade Salt and HCl Flow Rate 3 5 5 0 L min pH Raise pH Lower pH Pump Speed PS 10 PS 8 PS 6 PS 4 PS 2 PS 0 PS pH Raise pH Lower pH Pump Speed PS 10 PS 8 PS 6 PS 4 PS 2 PS 0 PS pH Raise pH Lower pH Pump Speed PS Lowering the flow rate will increase the ppm Raising th...

Page 10: ...ity of the inflow water If the hardness of the inflow water is less than 80 ppm scale will build up very slowly and the system may not require maintenance for many years Using the incorrect salt can cause mineral scale to build up very quickly If mineral scale does build up the electrical current required to generate a free chlorine solution of hypochlorous acid will be disrupted When to do Mainte...