background image

Bedienungsanleitung

Operating Instructions

Notice d'utilisation

Gebruiksaanwijzing

Explosionsgeschützter Datenlogger 

für Temperatur und relative Feuchte.

Intrinsically Safe Data Loggers for Temperature

and Relative Humidity

Enregistreur de température et d'humidité pour

zones à risques d'explosion 

Explosieveilige datalogger voor temperatuur en

relatieve vochtigheid

Ex 171-0 [°C]

Ex 171-3 [°C; %rF]

Ex 171-0 [°C]

Ex 171-3 [°C; % rH]

Summary of Contents for Ex 171-0

Page 1: ...tenlogger für Temperatur und relative Feuchte Intrinsically Safe Data Loggers for Temperature and Relative Humidity Enregistreur de température et d humidité pour zones à risques d explosion Explosieveilige datalogger voor temperatuur en relatieve vochtigheid Ex 171 0 C Ex 171 3 C rF Ex 171 0 C Ex 171 3 C rH ...

Page 2: ...ce 14 5 Data transmission 15 6 Battery change 15 7 Regular inspection and maintenance 15 8 Repair 16 9 Guarantee 16 10 Liability 16 11 Applications in Ex areas 16 12 Ex Data 17 13 Technical data 18 13 12 For further information on Software and operation please refer to the Software module operating instructions ...

Page 3: ...on and precautionary advice which for the described conditions must be taken into consideration to guarantee safe operation 2 Faults and Damage If there is any reason to suspect that the safety of the equipment has been affected then it must be immediately withdrawn from use and precautionary measures taken in order to prevent any further use of the equipment in the hazardous area until such time ...

Page 4: ...ata loggers Ex 171 0 and Ex 171 3 measure and store up to 55 000 measurements and have a battery life of up to four years Applications in hazardous areas of for example the chemical and pharmaceutical indu stry are in the monitoring of the atmosphere especially the documentation of atmospheric facts temperature C and relative humidity rH With in the hazardous area the use of the equipment is only ...

Page 5: ...val 2 sec 24h Memory 20 000 Power Supply Lithium Battery size AA U 3 6V Testo Order Code 0515 0018C Casing Material Anodised Aluminium Dimensions 131 x 68 x 26 mm 131 x 68 x 84 mm Storage Temperature 40 C 85 C Ambient Operating Temperature 35 C 70 C 10 C 50 C Standard Contents Data logger incl Battery starting magnet operating instructions calibration protocols Optional Accessories Software module...

Page 6: ...Z Nr 490B0100 02 01 ECOM Rolf Nied GmbH Industriestr 2 D 97959 Assamstadt Tel 49 0 6294 42 240 Fax 49 0 6294 42 24 90 E Mail sales ecom ex com Internet www ecom ex com ...