If the unit is improperly installed, it may cause a breakdown or an accident. Do not 
install in the following areas:
1) A place of frequent vibration or where vibration easily occurs. (Installation has to be a 

sound place where there is no vibration.) 

2) A place where the surrounding temperature exceeds 122°F or below 14°F.
3) A place where the temperature is freezing like a freezer.
4) A place where the is corrosive gas or use of chemical products.
5) A place where there is explosive dust or gas where it may occur.
6) A place where there is significant dust.
7) A place where there is significant humidity such as bathrooms, kitchens or other 

rooms that have over 90% of humidity or where it may occur.

Make sure to disconnect the power in the e vent of a power outage. When power supply 
is restored, the impeller may rotate rapidly causing an accident.

In using your fan, you should follow the 

IMPORTANT INSTRUCTIONS listed below. As 

part of these instructions we have used the word 

WARNING which indicates a hazard 

that, if not avoided, could result in death or injury.
IMPORTANT INSTRUCTIONS
When using electrical appliances, basic safety precautions should always be followed to 
reduce the risk of fire, electrical shock, and injury to persons, including the following:

Read all instructions before using this product. 
• Use this fan only as described in this manual. Any other use not recommended by the 

manufacturer may cause fire, electrical shock, or injury to persons.

• Extreme caution is necessary when the fan is used by or near children.
• Do not sit or stand on fan. Do not place objects on fan.    

  

          

• Do not insert or allow foreign objects to enter any ventilation or exhaust opening as 

this may cause electric shock, and/or a fire hazard.

• A fan has arcing parts inside. Do not use it in areas where gasoline, paint or flammable 

materials are used or stored. 

• Do not operate any fan with a damaged cord or plug. Do not operate the fan, which 

has been dropped, damaged or malfunctioned in any manner. Any repairs, or  
electrical, or mechanical adjustments should be made by a qualified electrician.

• Do not insert hand or object into the rotation part (impellers).
• Make sure to disconnect power before touching, moving or servicing unit.
• Properly mount fan to a secure surface before operating.
• Do not overload your circuits. Check amp draw relative to amps available on the 

circuit you want to connect the fan to.

• Do not allow any type of liquids to make contact with the fan.
• This product is intended for indoor use only.
•  Use only with electrical wiring that is in good working order and meets applicable 

codes.

• After completing installation, electric work, and duct work, perform the test operation 

to check if it operates normally.

• After injecting the power, if wing is not rotating or rotation is slow, cut off the power 

and check if the line connection is normally made.

• Check whether there is an abnormal sound or loss of wind during rotation.

• BEFORE CLEANING THE FAN DISCONNECT THE POWER CORD.
• Make periodic cleaning on filter absorption side & discharge head.

1. Outward Drawing

2. Capacity

3. Caution in Installation

Model No.

Suction A

Discharge B

C

D

E

F

G

736600

3.9

3.9

9.4

9.5

8.3

4.3

6.7

736605

5.5

5.5

11.1

11.9

9.4

3.5

6.8

736610

7.6

7.5

13.4

13.8

12.0

3.5

8.3

736675

10

10

14.2

14.7

8.7

6.3

8.66

736680

12

12

15.7

16.2

9.8

7.48

9.64

736685

12

12

15.7

16.2

9.8

7.48

9.64

Model No.

736600

736605

736610

736675

736680

736685

Volt / Phase

120v / 60 Hz 120v / 60 Hz 120v / 60 Hz 120v / 60 Hz 120v / 60 Hz 240v / 120 Hz 

Power Input: 

W

90

124

164

230

300

310

Amphere: A

0.8

1.12

1.49

1.94

2.54

1.3

Revolution: 

RPM (MAX)

3300

3225

3225

3090

3340

3340

Air Volume: 
CFM (MAX)

170

440

740

780

1060

1060

Static Pressure: 

Inch/Water(MAX)

2.01”

2.28”

2.30”

3.06”

3.54”

3.54”

Weight: Kg

2.8

3.0

9.0

8.0

9.5

9.5

1) When installing and carrying, be careful not to deform the impeller. If the wings are 

deformed, it will be unbalanced and cause noise and vibration.

2) Use a filter on the absorption axis to prevent dust, oil and other foreign substances 

on the impeller. (Filter selection may cause pressure loss for each type as well as the 
wind volume may be lowered.)

3) For installation on the ceiling, make sure to install an inspection hole of at least  

18” x 18” for repair and inspection. 

4. How to Install

Fan can be mounted to a floor, ceiling or wall. Attach fan to a sturdy surface like a stud 
or other solid wood. Do not attach to a weak surface like sheetrock.

In all cases use the fixed mounting bracket and appropriate nuts and bolts to  
attach the fan. 

5. Test Operation

6. Maintenance