Step 13. – Mount and Install UV Sterilizer
Locate the 3/4” NPT to 1” NPT flexible stainless steel connector. Connect the 1” end (black)
of the flexible stainless steel connector to the outlet assembly on the ecoTAC™ tank’s bypass.
It connects in the same way as a garden hose attaches to an outdoor faucet. Do not use
Teflon® tape or other thread sealants and do NOT over-tighten. Excessive force is not
required to obtain a good seal.
The other end (3/4” steel) of the flexible connector attaches to the inlet (bottom port) on the
UV disinfection chamber in the same manner. The flexible connector can be bent to reach
the UV chamber which should be mounted securely on the wall behind your ecoTAC™
media tank. The flexible connector is designed to be bent many times but not repeatedly
over and over. Doing so may reduce the structural integrity of the fitting.
Follow the instructions in the
Viqua UVMax D4 Premium Owner’s Manual Section 3.1
“Installing UV System”
to mount and install your UV sterilizer. Be sure that you install the
Summary of Contents for EP-600-ULT