.Operation introduction

Water heater

Operation introduction

1. Controller introduction

ON/OFF

   

MODE    UP/DOWN          

SET

  

TIMER

Heating mode

Data showing area

Timer on 

Timer off

Clock

Timer on/ off sign

defrosting

            button

  ---to turn on or turn off your heat pump. Long press 10 seconds for factory

      default setting. 

       and      button

-----up and down button to check or change setting.

Press these two button at the same time for 3seconds, lock the keyboard.

            button

  —Change setting. While use      or      button to check parameter, press 

button at the moment, could change the setting of current parameter. After 

finished, press      to confirm. 

Press       button alone, could come to clock setting. First set the hour data, 

and use       or      button to change the hour data.

Secondly press       again, to come to minute data setting. Still use      or  

button to change the minuted data. After that, press       to confirm.  

           button 

 ----Press       for 3 seconds in standby status, could enter for Force Defrost.

            button

 ----Button for timming.Integrating with up and down button, to set the time 

for turning on or turning off the heat pump.

 

2  Wire controller button definition

Summary of Contents for SWBC-3.0H-A/P

Page 1: ...AIR SOURCE HEAT PUMP WATER HEATER Installation Instruction Manual English Version ...

Page 2: ...formance Data 3 Ⅴ Dimension 4 Ⅵ Operation introductions 5 Ⅶ 17 Ⅷ 18 Ⅸ 21 To our customers before installation Product Introducing 1 Electric Circuit Wiring Diagram Installation instructions Maintenance CONTENTS Water heater Contents ...

Page 3: ...ponents without switching off the electrical supply to the unit Electric leakage switch protection device MUST be installed 3 It is forbidden to start any work on the electrical components if water or high humidity is present on the installation site 4 When the unit is being connected ensure that no impurities are introduced into the pipe work and the water circuits 5 All maintenance or repairmen ...

Page 4: ... will not cause pollution and no poison gas exhausting All Round The Year Hot Water Heat pump water heaters are not affected by seasonal climate provide hot water all year round even in cloudy or rainy days Durable and long lasting time Heat pump spare parts such as compressor and 4 way valve are made by famous brand manufacturer and casing panel is corrosion resistance very durable and long lasti...

Page 5: ...erature and high pressure of the refrigerant gas from the compressor to exhaust emissions such reciprocating cycle Power supply Hot water outlet Water inlet Compressor Heat energy pass to water Dis c harg e he a t equ i pment Absorbing air heat energy Ab so rbin g heat eq uipmen t Liquid tank Dry filter Expansion valve Ⅲ Work principle Water heater Performance Data Ⅳ Performance Data Water heater ...

Page 6: ...The dimension for air source heat pump water heater Ⅴ Dimension Water heater 4 ...

Page 7: ...n Change setting While use or button to check parameter press button at the moment could change the setting of current parameter After finished press to confirm Press button alone could come to clock setting First set the hour data and use or button to change the hour data Secondly press again to come to minute data setting Still use or button to change the minuted data After that press to confirm...

Page 8: ... LCD display as below Parameter data setting You could check and change the setting from any status as below steps 1 Press up down button for the parameter you want to change setting 2 Press button once and the right data flash 3 Use up down button to change the setting Press button again for confirm Ⅵ Operation introduction Water heater 6 ...

Page 9: ...er for timming ON flash press or to adjust the minute for timming ON After setting the minute for timming ON press once again to enter the hour setting of timming OFF After setting the timming OFF hour and minute press again to confirm current setting and return to default state In the state of Timming Setting press once it will clear timming ON OFF setting and return to default state Keyboard Loc...

Page 10: ...ve 3 Parameters 1 12Min 40Min 7 13 5 55 35 0 5 8Min 30 90Min Can adjust Temperature to enter to defrosting in heating mode 30 0 Can adjust Temperature to exit defrosting under heating mode 50 Remark Range Definition Tank water temperature setting 25 60 Can adjust Default Parameters 2 30 2 15 45 60 20 40 Can adjust Defrosting time Can adjust Can adjust Can adjust Can adjust EEV control manual or au...

Page 11: ...nti freezing protection I Winter anti freezing protection II Gas suction side temperature sensor 2 failure Exhaust temp sensor 1 failure Exhaust temp sensor 2 failure Exhaust 1 high temp protection Exhaust 2 high temp protection System high pressure protection System low pressure protection Water flow switch failure Power source wrong open phase Wire controller communication failure Defrosting PP1...

Page 12: ...nected Long press the timer button of LCD controller for 5 seconds See below pic Then input the password for example 12345678 of WIFI TP LINK 22233 The wifi should be your local wifi and your password of local wifi And press Start see below pic Your smart phone should near the controller to ensure easy connected for wifi Timer button a First way For Android System Ⅵ Operation introduction Water he...

Page 13: ...ch all wifi setting If connected successful it could show SmartLink Compelted as below pic If failed it could show time out as below pic then you have to repeat step 3 4 again a First way Ⅵ Operation introduction Water heater 11 ...

Page 14: ... for fast installation as well Input the passwords of your local wifi Other setting please refer to Android system as they are the same Remarks initial wifi setting may need a few times to complete Please try more times if once is not successful For IOS System 12 Ⅵ Operation introduction Water heater ...

Page 15: ... wifi HF LPB100 and connect it Open website of 10 10 100 254 input user name and password as below User name admin Password admin After that you could find below interface Select work mode change to STA mode And then press Save See below ref pic 13 Ⅵ Operation introduction Water heater ...

Page 16: ...ction Water heater b Second way for wifi setting Then select STA setting press Scan then press Save See below refer pic Please choose the safety and reliable local area network which available Then press OK to Confirm 14 ...

Page 17: ...i setting Make sure the Encryption Method choose WPA2PSK and Encryption Algorithm choose AES Input the password of your local area network Then press Save After finished all above steps come to Restart interface and press OK to confirm RESTART See below pic 15 ...

Page 18: ...i signal will never come out After wifi connected successful you could have inquire about heat pump status by below website http app xlink cn 9001 query html Or you could scan below QR Code to enter the website for Heat pump status checking Fast inquire only to check 1 or 2 heat pump units Agent research Able to check all the heat pumps as order Or visit below website http app xlink cn 9001 login ...

Page 19: ...tting of Parameter 40 default setting 50 deg c 6 3 Heat pump will turn on when S2 switch has well connected However S2 well connected and suddenly press the off button on the LCD controller Heat pump will stop for 3 minutes After 3 minutes heat pump continue to turn on if S2 Still has been connected 6 4 The timer function is out of validity when S2 switch is connected 6 5 Heat pump turns off when ...

Page 20: ... direction 1The air inlet and outlet can connect the φ150 air duct for air ventilation see below pic Water tank 1Water tanks should be placed where ambient temperature is above 0 1Can be installed outdoors or the top of the building based on the size of water tanks and the load bearing capacity of the building and so on 1Do not install water tanks in the pollution corrosive gases place 2 Unit inst...

Page 21: ...avoid the broken of water supply and pause valve Water system installation 1All the pipeline tubing should be matched as shown on the manual and in accordance with national corresponding construction standards 1Installation of water pipes should be straight and flat pipeline collocation should be rational ensure to minimize bending reduce the resistance loss of the water system 1Pipeline and conne...

Page 22: ...t the circulating water pump compressor fan motor runs after low level switch closed 1 During the unit operation circulating pump open When the unit stopped the circulating pump will be delayed 30 seconds then stop functioning 1 When water pumps open meanwhile open water return induction valve 10 minutes later test the return water temperature when the return water temperature water temperature 5 ...

Page 23: ...around should remain clean well ventilated Regularly clean 1 2 month the side air heat exchanger to maintain a good effect of heat exchange 7 Frequently check whether each part of the unit work normal or not check whether there is oil on the pipeline joints and charging valve to ensure that no refrigerant leakage 8 Do not piling up debris around the unit so as not to block from air inlet and outle...