background image

SYNAIRG

TM

 PURIFICATION               

 PLATE INSTALLATION

The Flair utilizes two SynAirG

TM

 purification 

plates. 

1. Remove (2) phillips-head screws.                  

 (220/240 volt only)

2. Remove the rear lint screen. 

3. Fully insert the SynAirG

TM

 purification plates  

(A & B) between the guides until they stop.

4. Re-install lint screen as shown below.

NOTE: The Flair’s SynAirG

TM

 purification plates 

should only be used in the Flair system.

CAUTION: Do not operate unit without one or 
both SynAirG

TM

 purification plate(s) properly 

installed. Doing so may void your warranty.

5

LINT SCREEN INSTALLATION

1. Always install bottom of lint screen first. 

2. The white lint screen tab should depress 

the safety switch arm towards the 
bottom of the unit.

Unit will not operate if safety switch is not 
depressed.

3. Fit top of lint screen into cabinet.

4. Secure with (2) phillips-head screws. 

(220/240 volt only)

a

b

1

2

3

Lint 
Screen 
Tab

2 Screws 
(220 & 240 volt only)

2 Screws 
(220 & 240 volt only)

Summary of Contents for Flair

Page 1: ...and operation Application Noteable Features Specifications Installation Operation Maintenance Warranty Living Air Electronic Air Purification Systems 100 110 220 240 volt Flair Systems EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 423 638 7246 www EcoQuest com ...

Page 2: ...______________ Phone ___________________________________________________________ CAUTION Disconnect power cord before servicing 100 110 volt models use 1 0 Amp slow blow fuse 220 240 volt models use 0 5 Amp slow blow fuse PE Location for Protective Earth Line CAUTION Do not operate unit without one or both SynAirGTM purification plate s properly installed Doing so may void your warranty To reduce ...

Page 3: ...eration Features Adjustable Fan Speed Control Sanitization Function Button Adjustable Ozone Control Balanced Ion Production Electrical 100 50 60 110 volt 60hz AC line operation Flair 110 volt 220 volt 50hz AC line operation Flair 220 volt 240 volt 50hz AC line operation Flair 240 volt 30 watts power consumption 24 to 30 KV 20 30 Khz ion generation pulsator Fixed 6 KV DC needle ion generator Mechan...

Page 4: ...ll effectively sanitize an unoccupied area PRE INSTALLATION AND INSPECTION 1 Remove unit from shipping carton 2 Remove all protective materials 3 Check for shipping damage and loose or broken parts 4 Read Owners Manual thoroughly prior to installation 5 Remove plates from the box and install plates See SynAirGTM Purification Plate Installation page 5 220 240 volt models skip to step 3 6 OPTIONAL P...

Page 5: ...only be used in the Flair system CAUTION Do not operate unit without one or both SynAirGTM purification plate s properly installed Doing so may void your warranty 5 LINT SCREEN INSTALLATION 1 Always install bottom of lint screen first 2 The white lint screen tab should depress the safety switch arm towards the bottom of the unit Unit will not operate if safety switch is not depressed 3 Fit top of ...

Page 6: ...ch of open area to allow unrestricted airflow Be sure power cord is not accessible to children to prevent injury 6 PLACING THE UNIT Place the unit as high as possible for maximum effectiveness On top of a bookshelf high cabinet etc An attractive wall mounted bracket is also available see figure A If raised placement is not available place unit as high as possible and elevate front of unit so fan b...

Page 7: ...vironment Under normal conditions it is not necessary to turn the ozone control indicator above the square footage of the environment 2 Keeping in mind the previous statement 1 adjust the purifier so the odor of ozone fades into the background 15 30 seconds after entering the environment 3 When the control is turned below the 100 square foot setting the ozone will be turned completely off the fan ...

Page 8: ...the edge nearest to you and slowly pull it straight out If you are in an environment where there are fats oils or grease such as in a kitchen start with cleaning with denatured alcohol and a soft bristle brush This will cut the grease without leaving a residue For all applications Clean with ammonia to remove contaminants Put the plate s into a shallow dish and pour enough ammonia into the dish to...

Page 9: ...hould stay illuminated as long as the unit is turned on 9 Removing the Chassis Changing the Fuse CAUTION Unplug unit from AC outlet A Remove the chassis from the cabinet by first removing the screw on the bottom of the cabinet B Slide the chassis out and place it on its side C The fuse holder is located on the right front side of the circuit board D Simply remove the fuse by gently pulling it from...

Page 10: ...new plates from your Dealer Electrical stainless steel contacts are not contacting the screen portion of the SynAirGTM purification plate s Inspect the unit for any loose connections Do not attempt to disassemble the unit beyond removing the chassis to replace the fuse page 9 or to perform routine maintenance page 8 Doing so may void your warranty 3 How am I able to know if the Frequency Type Ioni...

Page 11: ...r movement Symptom Visual haze of smoke and or particulate remain within the environment Problem Lack of ionization and or air movement 6 Unit does not operate Is the unit plugged in Are you sure the outlet is active Is the unit turned on Is the rear lint screen installed properly to depress the safety switch downward 7 Air flow is restricted or reduced Is the unit properly placed away from object...

Page 12: ...tions concerning your Living Air system please see your local EcoQuest Dealer If your unit is defective please contact EcoQuest International 310 T Elmer Cox Drive Greeneville TN 37743 or visit www EcoQuestIntl com for technical help Did you forget to register your Flair By registering you ll activate your warranty and your privacy is guaranteed Just fill out your warranty card and drop it in the ...

Reviews: