8
TECHNICAL DATA
Model
D850E
/R410A
D950E
/R410A
Mains
230 V / 50 Hz
Power consumption
W
960
1400
Current (
operation
)
A
4,15
6,5
Current (
at start
)
A
20
22
Water extraction
at
30 °C, 70 % RH
30 °C, 80 % RH
32 °C, 90 % RH
L/24h
52
60
63
61
76
81
Refrigerating agent R410A*
g
540 700
Airflow (
at high fan speed
)
m
3
/h
500
680
Operating temperature
°C
7 – 35
Dimensions
w x h x d
mm
660 x 750 x 345
Weight (
net
)
kg
37
39
Meets EEC directive 73/23/CE (LVD). Specifications may change without prior notice.
TROUBLE SHOOTING
If the dehumidifier does not operate:
• Make sure the unit is plugged in.
• Ensure the humidistat control is turned on.
If the unit is noisy:
• Make sure the dehumidifier is standing solidly and level.
If the unit is leaking:
• Check the drainage tube for correct fitting.
• Check for twists and bends in the drainage tube.
• Check the drainage tube for a sufficient slope.
• Check and make sure that the outlet of the drainage pipe is not under the water-
level in the drain.
* (EC) No 842/2006: R410A is a preparation of fluorinated gases covered by the Kyoto Protocol.
Its global warming potential (GWP) is 1975. See page 31.
Disposal
Waste electrical and electronic products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.