background image

 

Range 3030 

– 3031ARD 

Instruction manual

 

 

ECOSAFE | Date of the document : 26/06/2019 – Version : 01 

 

Connection to a ventilation system 

The air inlet and outlet are situated in the back of the cabinet. See the below outline.  

 

How to choose a ventilation or a filtration box ? 

 

Ventilation boxes

 are connected to the safety cabinet with a connecting kit (including a connecting sleeve, 2 hose clamps and 1 meter 

of  flexible  sheath)  ;  the  fan  included  in  the  box  extracts  the  toxic  vapors  contained  in  the  cabinet,  and  reject  it  to  the  outside  of  the 

building thanks to the roof or wall extraction.   

 

If you cannot reject the vapors to the outside, you need a filtration box.  

 

Filtration boxes

 are equipped with an activated carbon filter, which purifies the toxic vapors in the box, and rejects it in the room in a 

healthy fashion. Filtration boxes are delivered with the activated carbon filter that you need to renew once a year.  

 

Running without any mechanic ventilation 

It  is  possible  for  your  safety  cabinet  to  run  without  mechanical  ventilation.  However,  your  cabinet  has  to  be  placed  in  a  location  that 

provides its own ventilation system (at least 5 times the volume of the location, per hour).  

The cabinet itself and a radius of 2,5 meters directly around is a dangerous area subject to explosions.  

 

On the other hand, if the ventilation system of your cabinet is not running, you have to indicate it, by putting an etiquette on the cabinet, 

saying “Safety cabinet not connected to the mechanic ventilation” (etiquette is not provided).  

 

7.  SAFETY CONTROLS 

 

Your safety cabinet is a safety equipment. As to guarantee its perfect efficiency, you have to check the equipment regularly.  

Summary of Contents for 3030ARD

Page 1: ...Range 3030 3031ARD Instruction manual ECOSAFE Date of the document 26 06 2019 Version 01 0 Instruction manual For safety cabinet Picture Model 90 minutes Bench not included Model 3031ARD ...

Page 2: ...1 CONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 7 5 Storage Page 7 6 Ventilation Page 7 7 Safety controls Page 9 8 Spare parts Page 9 9 Recycling Page 9 10 Warranty Page 9 11 Control sheet for the user Page 11 ...

Page 3: ...ion openings with a connecting sleeve diameter 100 mm for an eventual connection Ventilation ducts with a thermo fuse Thermo expanding door seals allowing to insulate the content of the safety cabinet in case of a fire Self closing doors with the possibility to keep the doors open If the temperature rises to 43 C the doors are closed automatically External dimensions H 635 x W 605 x D 630 mm Stora...

Page 4: ... ensure that you also received a set of two keys Your safety cabinet has to be installed used and maintained as to guarantee the users protection Swing doors The swinging doors can be open by pulling the handle The automatic closing system allows the doors to be closed systematically after every use if the blocking doors system is not activated Door closing mechanism The door closing mechanism is ...

Page 5: ...h with green LED 2 Snooze and reset button 3 Status channel 1 with green LED Back view 4 Output Potential free switch channel 1 6 DC input 24V electrical power supply 7 Input level sensor channel 1 Technical features Dimensions H 105 x W 180 x D 55 mm Weight ca 620g Power supply 24V Switching power 24V 2A Power consumption Max 4W Operating temperature 5 C to 40 C Display LEDs ...

Page 6: ...ap The floater on your SafetyWasteCap might be stuck or unmovable by sticky or viscous fluids Check floater and level control mechanism constantly for dirt or contaminants The floater must be freely movable Clean and purge the floater if necessary with a suitable solvent or clean water Commissionning 1 Power supply Connect the Signalbox to your power supply using the delivered ac dc adapter 6 Now ...

Page 7: ...level During alert LED at the disc sensor flashes up please turn the potentiometer anti clockwise until the alert ends LED at the disc sensor off At next please turn the potentiometer clockwise and leave it close next to a position where the disc sensor alerts Put the sensor into a position above the fluid level to test the correct function If the sensor also alerts here please readjust Level aler...

Page 8: ...f your containment sump is approximately reduced by 3 liters 5 STORAGE Your safety cabinet is exclusively destined to store chemicals in laboratories industries schools in closed containers It must not store high concentrated corrosive products We remind you that the storage of corrosives can alter the quality of your safety equipment On the other hand we remind you that damages due to a bad use o...

Page 9: ...rifies the toxic vapors in the box and rejects it in the room in a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at leas...

Page 10: ... Contact us Locking system set of keys Contact us Standardized pictogram P N PICTOEN System to maintain the doors open Contact us Door closer mechanism Contact us Containment sump P N B148 Perforated cover plate P N C148 9 RECYCLING The safety cabinet can be entirely dismounted Various elements such as the steel can be recycled Ensure to respect the national and local waste disposal terms Those el...

Page 11: ... a third party The equipment had a modification or a repair by the user or a third party without any prior written authorization by ECOSAFE In case of a bad use of the equipment In case of a normal attrition of the equipment In case of a bad installation of the equipment In case of damage caused by the corrosion The activation of the warranty won t extend the term Our warranty stops if the custome...

Page 12: ...g of the doors works correctly The doors blocking system works correctly The mechanic ventilation system is running correctly if applicable The ventilation system is not obstructed The air inlet and outlet are clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The shelves and the containment sump are clean T...

Reviews: