1.  DESCRIPTION / USE 

 

The  chemicals  have  to  be  stored  in  safety  cabinets.  These  safety  cabinets  allow  storing  either  flammable  products,  acids,  bases  or 

toxics (low dangerous).

 

 

 

2.  TECHNICAL FEATURES 

 

Compliance :  

 

Compliance with INRS recommandations 

 

Compliance with the articles R. 5132-66 and R. 5132-68 of the Public Health Code 

 

Strandardized pictograms compliant with the standards ISO 3864, ISO 7010, NF X8.003 and the directive 92/58/CEE 

 

Technical features :  

 

Construction in 10/10th steel 

 

White epoxy paint RAL 9010 

 

Standardized pictograms provided 1x « flammables », 2x « corrosives » and 1x « toxics » 

 

Manual doors 

 

Locking system 

 

Shelves adjustable in height, every 100 mm 

 

Air inlet and outlet 

 

External dimensions : H 1825 x W 560 x D 545 mm 

 

Storage capacity : 120 liters 

 

Retention capacity : 20 liters 

 

Loading capacity : 50 KG per shelf 

 

Weight : 80 KG 

 

3.  INSTALLATION AND COMMISSIONING 

 

Installation 

 

The safety cabinet has to be installed on a flat surface that can bear its weight with the products inside.  

Ensure that the safety cabinet is correctly wedged, as for the cabinet not to topple. The eventual blocking has to be done by the user.  

The correct leveling of the cabinet must cart off any distortion of the frame, allow the doors to be strictly parallel compared to the frame, 

and take away any rubbing of the doors on the cabinet’s frame.  

 

The installation location must guarantee :  

 

That it is not exposed to any heat source 

 

That it is protected against moisture and that the ambient temperature of the location is neither less than 5°C, nor more than 

40°C 

 

Transport and handling 

 

The safety cabinet that you received has been protected and transported in optimal conditions, as to be protected from any damage.  

Summary of Contents for A1T

Page 1: ...Range 14 A1T Operating instructions ECOSAFE Date du document 19 06 2019 Version 01 0 Instruction manual For safety cabinet Model A1T ...

Page 2: ...ONTENT 1 Description Use Page 2 2 Technical features Page 2 3 Installation and commissioning Page 2 4 Internal equipments Page 3 5 Storage Page 3 6 Ventilation Page 3 7 Safety controls Page 4 8 Spare parts Page 5 9 Recycling Page 5 10 Warranty Page 5 11 Control sheet for the user Page 7 ...

Page 3: ...25 x W 560 x D 545 mm Storage capacity 120 liters Retention capacity 20 liters Loading capacity 50 KG per shelf Weight 80 KG 3 INSTALLATION AND COMMISSIONING Installation The safety cabinet has to be installed on a flat surface that can bear its weight with the products inside Ensure that the safety cabinet is correctly wedged as for the cabinet not to topple The eventual blocking has to be done b...

Page 4: ...acity per shelf is 5 liters Take care not to exceed the loading capacity per shelf of 50 KG 5 STORAGE Your safety cabinet is exclusively destined to store low risk chemicals in laboratories industries schools in closed containers It must not store high concentrated corrosive products or very flammable products We remind you that the storage of corrosives can alter the quality of your safety equipm...

Page 5: ... a healthy fashion Filtration boxes are delivered with the activated carbon filter that you need to renew once a year Running without any mechanic ventilation It is possible for your safety cabinet to run without mechanical ventilation However your cabinet has to be placed in a location that provides its own ventilation system at least 5 times the volume of the location per hour The cabinet itself...

Page 6: ...respect the national and local waste disposal terms Those elements should not be mixed with household waste 10 WARRANTY Your equipment holds a 12 months warranty against every manufacturing defect limited to ordinary conditions of use from the date indicated on the delivery note Our warranty can be applied only in case of manufacturing defects or hidden fault The warranty covers only the replaceme...

Page 7: ...n 01 6 In case of a bad installation of the equipment In case of damage caused by the corrosion The activation of the warranty won t extend the term Our warranty stops if the customer has not notified us in a 7 days term after seeing the fault date that the customer has to prove ...

Page 8: ...ectly The locking system of the doors works correctly The mechanic ventilation system is running correctly The ventilation system is not obstructed The air outlet is clean The standardized pictogram on the door is in good condition and visible The door hinges are lubricated The locking system is lubricated The shelves and the containment sump are clean Remarks Date By Signature ...

Reviews: