OEM
CAREL code +030221791 - rel. 2.1 – 21/09/07
3
1.
MODELS AND DESCRIPTION OF THE COMPONENTS
The code that identifies the model of humidifier is made up of 10 characters, with the following meaning:
K U E * * * * * * *
* The controller is configured for the maximum capacity of the KUE selected and can be modified using humiSet.
Example:
KUET3C00C0 = OEM UE KIT with three-phase cylinder, cleanable, 15 kg/h steam, for standard conductivity, revision level 0;
KUE0R0MP00 = OEM UE KIT, reduced, 1.5/3 kg/h steam, no cylinder, multiple pack, revision level 0.
KUETR0CC00 = OEM UE KIT, reduced, three-phase, 1.5/3 kg/h steam, no cylinder, with frame and controller configured for 3
kg/h, 400 V three-phase.
1.1
Description of the components
Fig. 1.1.1
KUE*R / KUE*1 / KUE*2 / KUE*3
no. description
1
Load-bearing frame
2
Cylinder
3
Drain solenoid valve
4
90° revolving drain connector
4a
Straight drain connector (supplied)
5
Supply tank + conductivity meter
6
Fill solenoid valve
Table
1.1.1
Cylinder field
of conductivity
A
B
C
D
E
(1~)
F
(1~)
0
= no cylinder
Size and steam production
R=
1.5/3 kg/h reduced
1=
1.5/3 kg/h
2=
5/8 kg/h
3=
10/15 kg/h (3~)
9 kg/h (1~)
4=
25/45 kg/h
Family prefix
Type of power supply
0=
no cylinder
S
=single phase
T
=three-phase
Revision level
Type of cylinder
Ø =
disposable or no
cylinder
C =
cleanable
Custom features
XX=
custom features
ØØ=
standard ver.
single pack
MP
=
standard ver
multiple pack
CC:
standard version
with frame and
controller configured
on board *