CHECK THE FOLLOWING POINTS BEFORE CONTACTING TECHNICAL SUPPORT.

 

  

SPECIFICATIONS

 

MODEL 

DD1EA SIMPLE  

Temperature Range 

 34°F ~ 95°F 

Dehumidification Extraction Rate 

15 pints/day (7 litres) (68°F, 60%RH) 

Water Tank Capacity 

4.2 pints 

Voltage 

110 - 120V~60Hz 

Net Weight 

13.2 lbs 

Gross Weight 

15.4 lbs 

Net Dimension (W x H x D) 

11.4” x 19.1” x 6.9”  

Gross Dimension (W x H x D) 

13.8” x 21.7”x 9.1”  

TROUBLESHOOTING

 

PROBLEM  

REASON 

SOLUTION  

No Power 

    

Dehumidifier is not plugged in 

or there is no power supply  

Plug the dehumidifier into mains and switch 

plug ON.  Check the main power supply  

  
 

 
 

Water Full/

Check Light On 

   

Filter clogged    

Check and clean or replace the filter  

The air inlet or outlet is blocked 

or covered  

Remove obstructions 

Low humidity condition 

Switch off unit and move to another room 

Water tank is full or installed 

incorrectly     

    Empty water tank or re-install correctly    

 

Water float out of position 

Restore water float back into position 

       Water  

Leaking 

    

Dehumidifier on uneven surface 

or water tank fitted incorrectly 

Ensure the dehumidifier is on a flat, even 

surface, use a spirit level to check, remove 

tank and replace correctly 

Filter clogged 

Clean or replace filter 

Damaged water tank 

Remove the water tank, fill with water and 

place on a hard even surface to test for 

leakage 

The continuous drainage is 

clogged or loose 

Check the continuous drainage hose and its 

connection 

Not Collecting 

Water 

  

Set humidity is reached 

Readjust the humidity settings 

Room is very cold or very dry for 

the current settings  

 

Readjust the humidity setting or increase the 

room temperature 

Check room temperature and humidity levels 

Filter dusty 

Clean the air filter or replace it 

Dehumidifier set up incorrectly 

Ensure unit is set up correctly (Quick Start Up) 

Room Temperature is too hot 

Room Temperature is too cold 

Open the window or door to ventilate 

Increase heat in the room 

Noisy

 

Water tank or filter fitted incor-

rectly  

Check and refit the water tank or filter 

Check unit is on an even level surface 

In the unlikely event of a problem with your product, please refer in the first instance to:  

ECOSEB TECHNICAL SUPPORT

  

www.ecoseb.com/support 

Summary of Contents for DD122EA SIMPLE

Page 1: ...DD1EA SIMPLE Formerly DD122EA SIMPLE US CA FOR MORE LANGUAGES PLEASE VISIT www ecoseb com userguide ...

Page 2: ...iture musical instruments and artwork by drying it out too much HIGH HUMIDITY High humidity indoors causes damp and condensation The damp left by condensation can damage plaster wall paper furniture vehicles timber windows doors and clothes It can be harmful to our health when bacteria thrives causing mould and fungus MAINTAINING SAFE LEVELS OF HUMIDITY It is important to maintain a consistent hum...

Page 3: ...tor lights up when the water tank is full or incorrectly installed 2 Power ON Indicator Indicates when the unit is ON 3 Humidistat Dial Select from POWER OFF LOW MEDIUM HIGH LAUNDRY CONTINUOUS MODE settings 4 Economy Turbo Switch Select TURBO or ECONOMY settings CONTROL PANEL 1 2 3 4 BACK FRONT ...

Page 4: ...ion voiding your guarantee STEP 3 ON OFF TO OPERATE UNIT Place the unit in an upright position on an even level surface Plug the unit into the mains socket Turn the humidity stat dial clockwise to select desired mode Power ON indicator lights up Turn anti clockwise to switch the unit OFF STEP 4 DRY LAUNDRY MODE Low Select to keep the room at a comfortable level Dries the air to approximately 70 RH...

Page 5: ...when conditions allows follow Steps 1 and 3 USEFUL INFORMATION After turning the dehumidifier OFF DO NOT remove the power plug from the power socket immediately allow the unit to cool down for a minimum 5 minutes to help protect the internal components When you first use your dehumidifier it will work harder to reduce the room humidity to it s target This is the time when it will produce the most ...

Page 6: ... clean water if needed Do not use detergent solvent abrasive or hot water to avoid damaging the dehumidifier Do not remove or damage the float in the water tank or the unit will not operate properly The Water Full light indicator illuminates if the water tank is not correctly in position Do not tilt the dehumidifier when removing the water tank You may use a hose with an inner diameter of 7 16 for...

Page 7: ...hygiene standards The frequency depends on the duration and conditions of operation To purchase a replacement filter please visit www ecoseb com STEP 3 CLEANING YOUR DEHUMIDIFIER Turn the dehumidifier OFF wait for the fan to stop and unplug the unit from the socket 2 Clean the surface with a soft damp cloth 3 Dry thoroughly with a towel after cleaning 4 Empty the water tank by sliding out from the...

Page 8: ... 11 Always unplug the dehumidifier when not in use or when moving location To disconnect the dehumidifier from the power supply grip the plug and pull from the power socket Never pull by the cord 12 Always empty the water tank before storing the unit away 13 Close supervision is necessary when the dehumidifier is used in the presence of children and pets 14 Do not run power cord under carpeting or...

Page 9: ...king Dehumidifier on uneven surface or water tank fitted incorrectly Ensure the dehumidifier is on a flat even surface use a spirit level to check remove tank and replace correctly Filter clogged Clean or replace filter Damaged water tank Remove the water tank fill with water and place on a hard even surface to test for leakage The continuous drainage is clogged or loose Check the continuous drain...

Page 10: ...s of merchantability or fitness for a particular purpose are limited to two years or the shortest period allowed by law but not less than two years EcoSeb shall not be liable for consequential or incidental damages such as property damage and incidental expenses resulting from any breach of this written limited guarantee or any implied guarantee Some States and provinces do not allow the exclusion...

Page 11: ... 2016 EcoSeb Inc All rights reserved www ecoseb com ...

Page 12: ... 2016 EcoSeb Inc All rights reserved www ecoseb com ...

Reviews: