www.ecosmartfire.com
12
ENGLISH
Ventilation & Efficiency
Ventilation
& Efficiency
Ventilation
EcoSmart™ Fires do not require any form of permanent fixture or fitting, such as a flue for ventilation, a
permanent connection or any kind of fixed utility for fuel supply.
Denatured Ethanol* is safe to burn indoors without venting, because its main by-products are carbon dioxide,
water steam and heat.
In a house of typical construction, that is, one that is not of unusually tight construction due to heavy insulation
and tight seals against air infiltration, an adequate supply of air for combustion and ventilation is provided through
infiltration. However, if the heater is used in a small room where less than
(A)
of air space is provided for each
(B)
per hour of heater rating (considering the maximum burner setting), the door(s) to adjacent room(s) should
be kept open or a window to the outside should be opened at least
(C)
to guard against potential build up of
indoor air pollution. Do not install or operate in a bathroom or any other small room.
Burner Kits
(A)
Cubic Meter m
3
Cubic Feet [ft
3
]
(B)
BTU
(C)
Metric mm
Imperial [in]
Minimum room size
Burner One
5.7
[200]
1000
25.4
[1]
The room cannot be less than 70m
3
[2472ft
3
]
per burner
.
Burner Two
5.7
[200]
1000
25.4
[1]
The room cannot be less than 25m
3
[1000ft
3
]
per burner
.
XL900 Burner
5.7
[200]
1000
25.4
[1]
The room cannot be less than 110m
3
[3884ft
3
]
per burner
.
XL700 Burner
5.7
[200]
1000
25.4
[1]
The room cannot be less than 100m
3
[3531ft
3
]
per burner
.
Around Burner
5.7
[200]
1000
25.4
[1]
The room cannot be less than 70m
3
[2472ft
3
]
per burner
.
Triple Burner
17.1
[604]
3000
76.2
[3]
The room cannot be less than 210m
3
[7416ft
3
].
Multiple Burners may be installed into a fireplace setting however the ventilation requirements must be
adhered to at all times.