background image

 

 

Chapter 2 - Hardware 

1.

 

ECO-3Mini exterior 

 

2.

 

Connection   

ECO-3Mini can communicates with ECO-IR by connecting router. 

ECO-3Mini can be connected up to 4 sets of ECO-IR. 

Summary of Contents for ECO-3Mini

Page 1: ......

Page 2: ...me Setting 10 3 2 2 Periods Setting 10 3 2 3 Deactivated date 11 3 3 Cycle Suspend 12 3 4 Mode Setting 13 3 5 Sleeping Time Setting 14 3 6 Humidity Setting 14 3 7 Temp Humidity Advance Setting 15 3 8 Temp Control Power 15 3 9 Current Value Setting 16 3 10 Name Setting 16 4 Setting 17 4 1 Time Setting 17 4 2 Engineer Mode 18 4 3 Link setting 18 Chapter 5 Common Settings 19 1 Schedule Setting 19 2 T...

Page 3: ...take turns running in fan mode Compressor turns off to achieve energy saving According to the actual test results effective energy saving rates up to 16 7 Infrared copy and control ECO IR can copy infrared code and control A C Users don t need to modify A C Digital output DO ECO IR which has built in 2 set of DO relays can stop supply power to device The application of ECO IR is installed in centr...

Page 4: ...4 Chapter 2 Hardware 1 ECO 3Mini exterior 2 Connection ECO 3Mini can communicates with ECO IR by connecting router ECO 3Mini can be connected up to 4 sets of ECO IR ...

Page 5: ...5 Chapter 3 Process Flow Diagram ...

Page 6: ... will run splash screen for 5 second and then enter screen 2 Main screen Main screen can know 4 sets of ECO IR s states 1 Current Time 2 Press setting button to enter setting menu 3 ECO IR Name 4 Deactivated state User can enter ECO IR Setting screen to control activated or deactivated ...

Page 7: ...ir conditioning power state on off 10 Press this area to enter ECO IR setting screen and set 11 When ECO IR communication occurred main screen will show error icon 12 Showing ambient temperature 3 ECO IR Setting screen 1 ECO IR name 2 Activated Deactivated button If ECO IR is deactivated screen will show non activated and ECO 3MINI won t communicate with ECO IR 3 Back to main screen 4 Temperature ...

Page 8: ...s to turn on or off DI mode have three modes button motion off 9 Manually operating A C function button on off cool fan dry 10 ECO IR setting menu 11 Trends recording ambient temperature power state A C mode and DI mode for the past 24 hours 12 Showing ambient temperature temperature setting humidity and current 3 1 Infrared copy Step 1 Press button which you want to copy function Step 2 ECO IR wi...

Page 9: ...work by schedule setting This switch and control menu time control button in the ECO IR setting screen are the same 5 Reference Advanced application If switch and reference turn on time control becomes one of condition For example time control and PIR are the condition If two conditions were achieved PIR detects people passed and this period is turned on in period setting A C power will turn on An...

Page 10: ...circle then enter the time you want to set by number keyboard Step 2 Switch will turn on automatically User also can turn off switch to deactivate manually 3 2 2 Periods Setting Set 16 periods on or off in weekly schedule 1 Select day which you want to set 2 Press the period you want to activate then the period will turn green background ...

Page 11: ...ate ECO IR won t operate on specific dates This function is suitable for festivals Step 1 Press the month button at the upper left and enter number Step 2 Press the day you want to set then the day will turn green background ...

Page 12: ...nd It means how long is a cycle The shortest cycle is 2 minutes Step 2 Set fan time in a cycle Step 3 Set start time and end time then cycle suspend will work in this period Step 4 Turn cycle suspend switch on Delay Fan Time To avoid multiple air conditioners turn fan in the same time user can set delay fan time to delay A C turning fan ...

Page 13: ... 2 IR Only Only infrared is controlled 3 Relay Only Only relay is controlled 4 IR Relay0 Infrared and relay0 control power are controlled together Relay1 control fan cool Control Delay Time Set ECO IR to delay working by 0 10 second DI Mode Motion Delay close power Idle time Last cool mode time If PIR didn t detect people motion idle time can delay turning fan mode Fan time Last fan mode time If P...

Page 14: ...automatic dehumidification in the period When cool mode that has dehumidification effect turns on dry mode won t turn on Step 1 Set up low limit humidity If humidity above up limit value ECO IR will turn dry mode on If humidity less than limit value ECO IR will return to original mode Step 2 Set start time and end time Step 3 Turn switch on ...

Page 15: ... will turn cool mode If ambient temp have dropped below 26 5 C ECO IR will turn fan mode Temp Humidity offset Set temp humidity offset if temp humidity have error 3 8 Temp Control Power According to ambient temp ECO IR turns A C power on off automatically Step 1 Set up limit temp If ambient temp higher than value ECO IR will turn A C power on automatically Step 2 Set low limit temp If ambient temp...

Page 16: ...ECO IR judges A C state and controls A C Step 1 Set standby current value Step 2 Set fan current value Step 3 Turn switch on 3 10 Name Setting Change ECO IR name in 10 words The name is stored in ECO 3Mini If you change the connected ECO IR the name won t change ...

Page 17: ... time Engineer Mode Set system Link setting Set the connection IP Language Change language Chinese English 4 1 Time Setting Set system time if time has error Step 1 Set time 20yy mm dd hr mi se Step 2 Select day Step 3 Press submit button ...

Page 18: ...eer Mode We suggest operating under the professional guidance 4 3 Link setting IP address you can set IP to connect the different ECO IR Status ECO IR activated or deactivated Displays Default OFF Show system error ...

Page 19: ...19 Chapter 5 Common Settings 1 Schedule Setting ECO IR setting screen schedule setting Turn switch on Enter time setting Set the periods start and end time ...

Page 20: ...20 Enter period setting Select day press period which you want to activated green background ...

Page 21: ...p control on Advance setting Temp setting up low range default 0 5 C Set Temp control range in the ECO IR setting screen For example temp setting up low range is 0 5 C and temp control setting is 27 C in the ECO IR setting screen If ambient temp have risen over 27 5 C ECO IR will turn cool mode If ambient temp have dropped below 26 5 C ECO IR will turn fan mode ...

Page 22: ... fan time Idle time Last cool mode time If PIR didn t detect people motion idle time can delay turning fan mode Fan time Last fan mode time If PIR didn t detect people motion fan time can delay turning fan mode Advance setting Sleeping time Set sleeping time to avoid PIR didn t detect people motion to turn A C off in a period ...

Reviews: