Configuration 

 

Join the EcoInsight/EcoSource to the EcoConnect 

 
Enter the join codes on each device. The PAN and Channel will be set automatically. 
 

Required Equipment 

Hardware 

 

An EcoCommander or EcoCommander Pro 

 

An EcoConnect 

 

An EcoInsight/EcoSource that has been wired 

 

Unbent paperclip or pen 

 

Join Process 

 

1.

 

Verify the EcoCommander or EcoCommander Pro is powered. 

2.

 

Verify the EcoConnect is powered. 

3.

 

Verify the EcoConnect is connected to the EcoCommander or EcoCommander Pro. 

4.

 

Verify the EcoInsight/EcoSource is powered. 

5.

 

Use a paperclip or pen and Figure 4 below to enter the join code on the EcoConnect. 

 

Figure 4: EcoConnect and Join Code 

 

6.

 

Verify the LED on the front of the EcoConnect rapidly blinks green. 

7.

 

If your device is an EcoSource, proceed to the next step. If your device is an EcoInsight, proceed to 
Step 13. 

8.

 

Use a paperclip or pen and Figure 5 below to enter the join code on the EcoSource. 

Summary of Contents for PST6000

Page 1: ...EcoWave Installation Guide PST6000 and PST6550...

Page 2: ...pment 2 Hardware 2 Regulatory Compliance 2 FCC Notice 2 Wiring the EcoInsight EcoSource 3 Wireless Installation of the EcoAir 6 Configuration 7 Join the EcoInsight EcoSource to the EcoConnect 7 Requir...

Page 3: ...structions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the equipment does cause harmful interf...

Page 4: ...code 5 Disconnect the existing thermostat if any 6 Use the voltmeter to verify the power is off It may not be possible to switch off transformer supply voltage on low voltage units Use caution when in...

Page 5: ...r 12 277VAC power from HVAC used to power the thermostat 2 C Common AC Common 3 AUX Auxiliary User defined 4 W1 Heat Strip Heat call or strip heat call depends on programming 5 Switched Power 1 W1 Y1...

Page 6: ...ight EcoSource Backplate Wired to HVAC Unit 21 Hook the EcoInsight EcoSource to the hinges on the right hand side of the backplate 22 Gently swing the EcoInsight EcoSource closed onto the backplate un...

Page 7: ...tationary e g sleeping in bed Position the EcoAir within 2 to 12 feet of their expected location If the occupants will move occasionally e g working at desk Position the EcoAir within 15 feet of their...

Page 8: ...paperclip or pen Join Process 1 Verify the EcoCommander or EcoCommander Pro is powered 2 Verify the EcoConnect is powered 3 Verify the EcoConnect is connected to the EcoCommander or EcoCommander Pro 4...

Page 9: ...boots 12 Verify that the LED on the front of the EcoSource is lit solid green Continue to Step 18 13 Use figure 6 to enter the join code on the EcoInsight Figure 6 EcoInsight and Join Code 14 Verify t...

Page 10: ...ront of the EcoConnect should change from blinking green to solid green This means the EcoConnect will no longer accept join requests from ZigBee devices 19 If configuring a multi bind system where mu...

Page 11: ...4 Hold the On Off button on the EcoAir until the EcoAir displays two digits on its screen This may take up to 10 seconds The displayed digits will be the last two digits of the EcoSource s serial num...

Page 12: ...to exit the Maintenance Menu Association is complete Continue to Step 12 Verify the Association 12 Activate heat mode on the EcoAir exact steps will vary by EcoAir firmware 13 Increase the set temper...

Page 13: ...blink red 10 Hold the On Off button on the EcoAir until the EcoAir displays two digits on its screen This may take up to 10 seconds The displayed digits will be the last two digits of the EcoSource s...

Page 14: ...e The text On should appear next to the smaller number See Figure 9 34 Hold the On Off button on the EcoAir until the EcoAir displays two digits on its screen This may take up to 10 seconds The displa...

Page 15: ...preface the PAN value with 0x such as 0x201 Backspace was used while typing the zb command Re enter the zb command without using backspace The ShortAdd shows the default value of 0xFFFF The EcoInsight...

Reviews: