background image

ECOsmarte Planet Friendly® | 612-866-1200 | ECOsmarte.com | Bloomington, MN

4

ECOSMARTE

CHAMBER

Cut ozone line at least 3” from the tee. Glue 1 1/2” slip x 3/4” threaded adapter into the end of the electrode 

chamber. Apply glue to the threaded end of 3/4” thread x 3/4” barbed adapter and quickly assemble fittings. 

(See diagram) Glue barbed end of the adapter to clear the ozone line. Repeat process for the opposite end 

of the electrode chamber. You electrode chamber is either 11/2” or 2”. The CO2 Chamber is 2”.

Installing an ECOsmarte Programmable Spa System

For Spas, Swim Spas, and Endless Pools®

The 

Electrode Chambers

 may be installed 

anywhere on the ozone line reduced down 

between 3/8” and 1” with our Quick Change 

Unions. The 

ECOsmarte Electronic Box

 can 

be installed indoors or outdoors, but keep the 

box close to the spa or pool for easy access. The 

Electronic Box

 is water-resistant and comes 

with prewired leads connected to the 

Electrode 

Chamber

. If the installation requires any 

additional wires, you may order it from your local 

ECOsmarte dealer

 or the 

ECOsmarte Factory

.

Small Pools, Endless Pool®, and Swim Spas will require a 110v GFCI outlet within 10 feet of both the 

ECOSmarte control box and chambers. This outlet used on the Endless Pool® or the Hydroworx® is US 

Building Code since 2009.

For Spas Equipped with Ozone Line (Specify 110v or 220v) or Ozone Spa Shell Fittings

This Is A Side Stream Loop As With Ozone, Goes From Pipe To Ozone Jet

Note: Most spas are “ozone ready” even if you do not have ozone installed. Elbows may be required to 

complete installation where space is limited. Normally two cuts are not required.

To Jet

From “T” or Tap

3/4” Ozone Tubing 

to Jet

CO2 Chamber

Allow For 30 Inches 

of Vertical Space To 

Fit Chambers 

Electrode Chamber

3/4” Ozone Tubing 

From “T” or Tap

3/4” Clear Tubing to Jets

3/4” Threaded x 3/4” Barbed Adapter

1 1/2” - 2” Slip x 3/4” Threaded Adapter

Oxygen “OXIDIZE”

(Black/ White Paired Leads)

Copper “IONIZE”

(Red/ Green Paired Leads)

1 1/2” - 2” Slip x 3/4” Threaded Adapter

3/4” Threaded x 3/4” Barbed Adapter

Cut the line at least three inches from the Tee

Summary of Contents for Endless Pools

Page 1: ...ermine the proper location for the control box electrode chamber requires 11 of pipe space after the pump and CO2 chamber requires 7 of pipe space after the Electrode Chamber The CO2 chamber will be i...

Page 2: ...out The male ends of the unions are attached to the chambers out of the box They will be glued onto the freshly cut ends of the pipe Before gluing slide the ends onto the pipe and check to see if the...

Page 3: ...tep 4 Connect the chamber wires from the Control Box to the electrode chamber Attach each wire to one electrode bar as seen in the picture below BLACK AND WHITE LEADS TO TITANIUM RED AND GREEN LEADS T...

Page 4: ...ber If the installation requires any additional wires you may order it from your local ECOsmarte dealer or the ECOsmarte Factory Small Pools Endless Pool and Swim Spas will require a 110v GFCI outlet...

Page 5: ...eter Your programmable ECOsmarte box will overcome those manufacturers without ozone programming and allow you to program six to eight hours oxygen per day 1 1 1 ECOsmarte Copper Oxygen Chamber T from...

Page 6: ...read the regulator on to the tank as far as possible by hand Use a wrench to finish securing the regulator if necessary If you feel that you need excessive force to tighten the regulator unscrew it an...

Page 7: ...OT be visible The Programmable System is now fully installed and you can begin balancing the water levels and setting the Control Box as shown in your owner s manuals Inground pools over 10 000 gallon...

Page 8: ...ool 10 00A 4 00P Oxy 10 00A 4 00P Ion 10 00A 10 10A From Next Week WEEKLY IONIZE 2 22 20P 1 01 2020 Pool 10 00A 4 00P Oxy 10 00A 4 00P Ion 10 00A 10 16A From Next Week DAILY CO2 Use Keys To Set Run Ti...

Page 9: ...will now look as shown Actual ION hours required to get your first residual will be a function of total gallons TDS total dissolved solids and pH below 7 2 of your pool A water test seeking 0 5ppm co...

Page 10: ...the Owner s Manual Remember to shut off the Electronic Box when water is not circulating through the Electrode Chamber The Copper Electrodes will continue to ionize if the electrodes are in solid cont...

Page 11: ...ecosmartecloud com 1 Phillips Screwdriver 2 Flathead Screwdriver 3 1 2 Drill Bit 4 1 2 Tap ABSOLUTELY INCOMPATIBLE PRODUCTS Any Algaecide w metal Any SOLID CHLORINE Any metal remover Scale Control or...

Page 12: ...ill allow you to connect to your smart phone and display the real time pH level and adjust settings remotely There is currently a waiting list for 2021 Go To Our Interactive Website or Download Our Fr...

Page 13: ...ECOsmarte Planet Friendly 612 866 1200 ECOsmarte com Bloomington MN 13...

Reviews: