1.    Basic technical parameters  

2. Application 

Radiating panels are designed for heating of large rooms, especially industrial halls, workshops etc., warehouses, stores 
and social and athletic halls. It can be used for local heating of defined areas (zone heating). 

Type  

Power

 W 

Voltage

 V 

Protection class 

IP 

Dimensions 

Weight 

kg 

ECOSUN SB09s 

900 

230V 1N 

I IP 

X4 

1500 x 130 x 50 

ECOSUN SB12s 

1200 

ECOSUN SB18s 

1800 

230/400V 

3N 

1500 x 230 x 50 

10 

ECOSUN SB24s 

2400 

ECOSUN SB30s 

3000 

1500 x 330 x 50 

14 

ECOSUN SB36s 

3600 

Type 

Spacing  

Note  

ECOSUN SB09s 

40 x 1000mm 

   

ECOSUN SB12s 

 -  hole diameter in fixtures 6mm  

ECOSUN SB18s 

100 x 1000mm 

 -  do not touch radiating surface of th panel with dirty hands when manipula-

ting 

ECOSUN SB24s 

   

ECOSUN SB30s 

200 x 1000mm 

   

ECOSUN SB36s 

   

Bedienungs-  und Montageanleitung 

 

Elektrische Strahlplatte ECOSUN 

SB09s — SB12s — SB18s — SB24s — SB30s — SB36s

 

N347/R02 (10.3.12) 

Summary of Contents for SB09s

Page 1: ...tection class IP Dimensions Weight kg ECOSUN SB09s 900 230V 1N I IP X4 1500 x 130 x 50 6 ECOSUN SB12s 1200 ECOSUN SB18s 1800 230 400V 3N 1500 x 230 x 50 10 ECOSUN SB24s 2400 ECOSUN SB30s 3000 1500 x 3...

Page 2: ...nvection occurs and this heat will irreversibly damage the electrical components of the terminal strip 4 Panel connection see fig 1 Electricity is distributed by CYKY cables Cables can be connected lo...

Page 3: ...nting frame in such a position that the opening for the locking screw is accessible Slide one side of the panel onto the lower hooked part of the frame Then slide the other side of the panel onto the...

Page 4: ...nation of the radiating surface or use clean textile gloves After installation remove the foil protecting the heating surface The environ mental temperature of the surrounding air of the radiating pan...

Page 5: ...30 x 50 14 ECOSUN SB36s 3600 2 Anwendung Die Strahlplatten sind f r die Heizung von gr eren R umen insbesondere in Industriehallen Werkst tten Lagern Gesch ften und in den Kultur und Sporthallen usw b...

Page 6: ...iegende Punkt der Platte ist Bei der Neigung erfolgt h here W rmekonvektion und diese W rme w rde die Elektroanlage des Klemmbretts irreversible besch digen 4 Anschluss der Platte siehe Abb 1 Die elek...

Page 7: ...feuchten L ppchen mit Surfactant beschr nkt 6 Montage mittels den Halterrahmen Den Montagerahmen so befestigen dass das Feststellschraubeloch zug nglich bleibt Eine Seite der Platte auf den Halter auf...