16
3.16 Description of Screen Displays
3.17 Description of Alarms
SCREEN DISPLAY
DESCRIPTION
FINAL CLEANING
The stove is switching off, the cooling phase is not yet completed
ON
The ignition phase has started,the pellets are loaded into fire pot
WAITING FOR FLAME
The pellet’s are ignited by the hot air passing through the ignition candle
FLAME PRESENT
The flame is visibile in the fire pot
WORKING
The stove has completed the switch ON phase; you can now change the power
MODULATION WORKING
The set room temperature has been reached
T ON
The room sensor is off or an external thermostat has been connected
COOLING/WAITING FOR START
The stove is cooling DOWN. When stove has cooled down it will start automatically.
ON/WAITING FOR RESTART
The switch ON phase, when the stove is warm, started. The operation is same of
phase ON
HOT SMOKE
The max temperature of smokes is reached: to reduce temperature, feeding pellets
and air draft reduce at POWER 01
OFF
The stove is off
IMPORTANT
IF DISPLAY SHOWS “HOT SMOKE“ THERE CAN BE PROBLEMS IN THE
COMBUSTION OF PELLETS. PLEASE CONTACT A SERVICE TECHNICIAN.
WARNING
REASON
SOLUTION
PELLETS FINISHED
ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and refill if
necessary.
• The raio-motor does not load
pellets.
• Empty the hopper to check that no foreign objects have fallen
inside which could prevent the correct functioning of the
auger.
•
Pellets not loading.
• Regulate the pellet setting.
•
IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
BLACK - OUT
• No electricity supply during
working phase.
• Press the off button and repeat switching on the stove.
•
IF THE PROBLEM CONTINUES, CONTACT YOUR LOCAL
SERVICE TECHNICIAN.
NO IGNITION ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and refill if
necessary.
• Setting of pellets and of intake
during ignition phase insufficient
•
Contact local Service Technician
• The resistance for lighting is
defective or not in position
•
Contact local Service Technician
LOW FLAME ALARM
• The pellet hopper is empty
• Check whether there are pellets in the hopper and refill if
necessary.
• Bad setting of pellet and air
during ignition
•
Contact local Service Technician
FAN RPM ALARM
• The revolution of smoke fan
lowering more than 15% of speed
to fan congestion
•
Contact local Service Technician