30
Side of Unit (B)
100mm
Rear wall to Lined Flue (D, L, J)
50mm
Rear wall to Unlined Flu (D, L, J)
75mm
Rear of Unit (M)
100mm
Rear corners (Corner Installation) (G) 120mm
Floor protection (from glass) (C)
150mm
2.3
Minimum Clearance to Combustibles
2.4
Location of the Pellet Fire
Installation of the Ecoteck Monica Plus Freestanding Wood Pellet Burning Heater should
be undertaken by an experienced installer. Please read the Monica Plus Owners/Technical
Manual thoroughly before commencing installation as failure to follow the instruction could
cause damage to the pellet fire or property.
2.5
Positioning the fire:
Generally Monica Plus should be installed in a centrally located position within the home. When
deciding where to position the appliance in your room you need to consider the following:
2.6
Location of a power source
•
Monica Plus has a convection fan which blows air through tubes in the direction that
the fire faces, for optimum performance this location should be in a large room centrally
located.
•
Monica Plus must be installed on a non-combustible surface. This surface must protrude
150mm from the front of the closed pellet fire door.
•
Monica Plus has been Safety Tested to AS/NZS 2918 using the Davins manufactured
flue. Test Report ARS 05/1185. Installation is not exclusive to these nominated kits,
though alternative flue should only be considered following consultation with your local
council.
•
Please consult page 30 for the required clearances to combustible material also ensure
the position of structural elements near the proposed flue.
•
Because of the positive pressure in the flue, sealing of all 75mm stainless joints is
mandatory – use high temperature Maniseal. Both inner and outer flue joints must be
riveted.
•
Seismic Restraint: Please view page 33 for requirements.
•
Warranty: To validate warranty following installation a copy of the completed Warranty/
Producers Statement must be forwarded to: Nature’s Flame- Fax (03) 348 1743.