Report on the performance testing of the Serinus 30 ambient air quality
monitoring system manufactured by Ecotech Pty Ltd measuring CO, Report
no.: 936/21221977/D_EN
EP_Ecotech_Serinus30_en.docx
Performance criterion
Minimum requirement
Test result
Com-
pliance
Page
The difference between the
measured values obtained by
feeding gas at the sample and
calibration port shall not ex-
ceed the requirements listed in
Table 2 of VDI Guideline 4202
Sheet 1 (September 2010).
In case of measuring systems
with a converter, the converter
efficiency shall be at least
98 %.
This test item does not apply as the
measuring system does not use a
In case of NO
X
measuring sys-
tems the increase of NO
2
con-
centration due to residence in
the measuring system shall not
exceed the requirements listed
in Table 2 of VDI Guideline
4202 Sheet 1 (September
2010).
Not applicable as the measuring sys-
The expanded uncertainty of
the measuring system shall be
determined. The value deter-
mined shall not exceed the cor-
responding data quality objec-
tives specified in the applicable
EU Directives on air quality as
listed in Annex A, Table A 1 of
VDI Guideline 4202 Sheet 1
(September 2010).
The determination of uncertainty was
performed in accordance with DIN EN
14626 (2012) and is detailed in sec-
tion 7.1 8.6 Total uncertainty
in accordance with Annex E of DIN
8.4
Requirements of Standard DIN EN 14626
Neither the response time
(rise) nor the response time
(fall) shall exceed 180 s. The
difference between rise and fall
response time shall not exceed
10 % relative difference or
10 s, depending on which val-
ue is larger.
The maximum permissible response
time of 180 s is exceeded at no time.
The maximum response time deter-
mined is 52 s for system 1 and 56 s
Summary of Contents for Serinus 30
Page 120: ...Serinus 30 Kohlenmonoxid Analysator Benutzerhandbuch Version 2 1 www ecotech com...
Page 121: ...Serinus 30 Benutzerhandbuch 2 1 Seite 2 Diese Seite wurde absichtlich frei gelassen...
Page 135: ...Serinus 30 Benutzerhandbuch 2 1 Seite 16 Diese Seite wurde absichtlich frei gelassen...
Page 181: ...Serinus 30 Benutzerhandbuch 2 1 Seite 62 Diese Seite wurde absichtlich frei gelassen...
Page 197: ...Serinus 30 Benutzerhandbuch 2 1 Seite 78 Diese Seite wurde absichtlich frei gelassen...
Page 229: ...Serinus 30 Benutzerhandbuch 2 1 Seite 110 Diese Seite wurde absichtlich frei gelassen...
Page 237: ...Serinus 30 Benutzerhandbuch 2 1 Seite 118 Diese Seite wurde absichtlich frei gelassen...