5. OPERATION MANUAL 
 

The customer has to provide water supply and electricity to the installation. 

 - The customer monitors for leaks and controls the operating pressure in the system.  
- Adjust the boiler or room temperature depending on the operating principle of the 
installation and personal preferences. 
- Upon departure from the parameters calls to authorized service. 
- The service is performed by specialists familiar with the structure, management and 
operation of the device. 
- When the electric power stops and restores again, the electric boiler automatically starts 
again. 
 

6. CONNECTING TO THE ELECTRIC NETWORK 
 

- Connecting the electric switchboard to the power supply network and the boiler electric 
installation assembly should be carried out only by an expert with the necessary 
qualification. The power supply is connected through not severable joint according to the 
connection diagram. The cross-section of the power supply cable should be selected in 
accordance with the boiler power (see Table 4, page 14). 

  
7. COMMISSIONING 
 

-  Boiler  startup  is  possible  after  performed  control  on  the  good  working  order  of  the 
connections  to  the  heating  system,  checkup  of  the  electrical  connections  and  the  external 
line. 
-  Check  up  whether  the  valves  and  taps  of  the  heating  circuit  are  open,  check  up  also  the 
water pressure in  the system. Switch on the automatic fuse of the electric boiler and preset 
the  desired  temperature  of  the  boiler  and  the  indoor  temperature  controller  or  programmer. 
Servicing of the indoor temperature controller is  done according to the instructions thereto. 
The heating systems may be filled in only by water or mixture of water and antifreeze. Oil 
should not be used. 

 
 

8.  CONDITIONS  OF  COMMISSIONING  AND  UNDERTAKING  GUARANTEE 
MAINTENANCE – GENERAL TERMS: 

 

The  electric  boiler/module  is  mounted  by  consoles  only  on  a  wall  that  can  bear  its 
weight.  The  boiler  location  should  be  selected  in  a  manner  to  secure  access  – 
technological tolerance from its all four sides is shown on Fig. 6 page 13,

 

the distances 

being different for the various rated powers. 

 

1.

 

Boiler  should  be  mounted  at  a  place  suitable  for  servicing  (free  access  thereto)  and 
possibility of opening the front lid. 

2.

 

Boiler should be mounted suspended on the wall at  minimum height  of 1 m  off the 
floor. 

Summary of Contents for 10 MRT

Page 1: ...E WITH THREE STAGE ELECTRONIC CONTROL PASSPORT OF ELECTRIC BOILER WITH THREE STAGE ELECTRONIC CONTROL ECOTERMAL MRT MODULE T 6 8 10 12 15 18 22 24 30 kW Bourgas 8000 47 Slivnitsa Str tel 056 814 681 056 814 215 fax 056 814 584 E mail sales ecotermal bg com www ecotermal com ...

Page 2: ... 8 7 Commissioning 8 8 Conditions of commissioning and undertaking guarantee maintenance 8 9 Diagrams and tables 10 15 9 1 Method of connecting of story local heating Fig 1 10 9 2 Method of connecting the system to a solid fuel boiler Fig 2 10 9 3 Structure of the electric boiler from 6 to 30 kW Fig 3 11 9 4 Structure of the electric module from 6 to 30 kW Fig 4 12 9 5 Control panel Fig 5 13 9 6 T...

Page 3: ...ay occur and the producer shall not be liable thereof In case of failure contact the service organization Unprofessional intervention may damage the boiler For correct functioning safety and long term operation secure prophylactics at least once a year In case of damages incurred by unprofessional assembly as well as upon noncompliance with the regulations and the operation manual the producer is ...

Page 4: ... board which corresponds to the difference between the set and the measured temperature This signal is in the 4 20 mA range Because both the regulators room and boiler are interconnected in cascade system this signal goes as a setpoint at the boiler thermo regulator s input which in turn controls the temperature of the water in the boiler therefore the more the room temperature approaches the set ...

Page 5: ...ple for electric boiler then it is not required to be mounted room thermo regulator In this case jumper J1 which placed on the main board is switched to pos 2 and by trimmer potentiometer W pos 12 the temperature is set In all other cases jumper J1 is placed in pos 1 4 2 TECHNICAL CHARACTERISTICS Power Supply 240V АС Maximum permissible operating current of the power relays 16А 250V The outlet ele...

Page 6: ...ontact external clock for timing of operation of the boiler in a closed contact In case that clock is not used these power wires are short circuit with a bridge X3 is connected to the boiler temperature sensor The sensor is polar you must follow the indicated polarity when connected In a reverse connection does not fail but the temperature is unreal To connect x8 to advanced management another six...

Page 7: ...order not to prevent the normal operation of the programmable thermo regulator The water temperature in the boiler is adjusted manually by the user and doesn t depend on the ambient temperature The thermostatic valves influence the boiler regulator by dosing the consumed heat power and the room temperature influences the duration of the boiler operating time An advantage of this method is the conv...

Page 8: ...startup is possible after performed control on the good working order of the connections to the heating system checkup of the electrical connections and the external line Check up whether the valves and taps of the heating circuit are open check up also the water pressure in the system Switch on the automatic fuse of the electric boiler and preset the desired temperature of the boiler and the indo...

Page 9: ... 5 Banjo fitting connections should be mounted on the boiler intake and the outlet 6 Hydraulic test should be carried out at an index of 1 25 above the operating pressure 7 Upon assembly it is necessary the adjustments of the boiler and the blocking thermostats to be checked up The actual control is done during the warm test 8 The guarantee shall be effective as from the commissioning date but not...

Page 10: ...ff valve 9 Safety valve by pressure 4 Electric heater 10 Solid fuel boiler 5 Electric boiler 11 Expansion vessel 6 Circulation pump 12 Manifold Box Method of connecting of story local heating Fig 2 1 Air bleeder 7 Safety valve 2 Electric heater 8 Shut off valve 3 Electric boiler 9 Manifold Box 4 Expansion vessel 5 Circulation pump 6 Water filter ...

Page 11: ...eaker with additional protection 5 Emergency blocking Thermostat 6 Air Bleeder 7 System control 8 Water Container 10 Heaters 11 Circulation Pump 12 Control Panel 13 Pressure gauge valve 14 Expansion Tank 15 Thermostat Pocket 16 Thermostat bimetallic 17 Pressure switch 9 Pressure gauge ...

Page 12: ... Automatic Breaker with additional protection 5 Emergency blocking Thermostat 6 Air Bleeder 7 System control 8 Water Container 9 Pressure gauge 10 Heaters 12 Control Panel 13 Pressure gauge Valve 15 Thermostat Pocket 16 Thermostat bimetallic 17 Pressure switch ...

Page 13: ...LED Indication of activated emergency thermostat 4 LED Indication of circulation pump condition 5 Button set current temperature 6 Pressure gauge 7 Potentiometer of boiler s temperature 8 LED Indication Second Stage ON 9 LED Indication Third Stage ON MRT MODULE T 6 30 KW Fig 6 ...

Page 14: ... 22 24 30 Commutations level pcs 3 3 3 3 3 Boiler body volume dm3 8 9 8 9 8 9 8 9 8 9 Supply voltage V 240 400 240 400 400 400 400 Maximum operating pressure Bar 2 5 Test pressure Bar 4 0 Regulation of heat medium temperature C 30 90 Room temperature control C 5 30 Connection pipes dimensions G 1 Efficiency index 99 30 Р kW Iheater A Cross section mm2 Ifuse A 6 8 33 5 x 2 5 10 8 11 11 5 x 2 5 16 1...

Page 15: ...modules Model Power kW Weight kg Model Power kW Weight kg 6 MRT 6 29 0 6 T 6 22 0 8 MRT 8 8 T 8 10 MRT 10 10 T 10 12 MRT 12 12 T 12 15 MRT 15 29 5 15 T 15 22 5 18 MRT 18 29 5 15 T 18 22 5 22 MRT 22 31 0 22 T 22 24 0 24 MRT 24 33 0 24 T 24 26 0 30 MRT 30 33 0 30 T 30 26 0 MODEL EQUIPMENT MRT Module Т Expansion tank Circulation pump Safety valve Blocking emergency Thermostat Air bleeder Mounting bra...

Reviews: