The High Performance filter is placed on the left hand side.

The ceramic filter is placed on the right hand side.

 

• 
• 

 

 

 

 

  
• 

Turn of the systems water source. Release water pressure by opening a connected 

tap. It’s a good idea to place a bowl or a towel under the purification system before 

opening the filter houses.
Open the ceramic filter housing using the enclosed tool.
Remove the filter/filters from the filter housing(s). Handle the ceramic filter with great 

care – the 6 ceramic candles can easily break.

CLEANING THE CERAMIC FILTER:

Use the enclosed cleaning brush or the pad to clean the 6 filter candles with cold 

water. Do not use soap! Put the cleaning brush around each candle, one at a time, 

and rub their surface a couple of times. Put the filter back in the filter housing. Make 

sure to place the filter in the correct direction – the black manifold should be 

upwards (as on the illustration of the cartridge assembly).

FILTER REPLACEMENT:

Replace all of the 6 ceramic candles with new ones (loosen them carefully by 

unscrewing them). Replace the High Performance filter. Put the filters back in the 

filter housings. Make sure to place the filter in the correct direction – the black 

manifold should be upwards (as on the illustration of the cartridge assembly).
Re-attach the filter housing to the purification unit. Tighten with the enclosed tool 

(it’s sufficient to tighten by hand). 
Make sure the housing is placed correctly. If the housing is attached askew, or the 

O-ring or filter is placed incorrectly, a leak will probably occur.
Open the water flow [

1

] into the purification system. Turn on the water and let the 

water flow for about 3 minutes (this removes dirt, particles etc).
Make sure that there are no leakages from the filter housings.

FILTER CLEANING/REPLACEMENT

NOTE! THE UNIT DOES NOT TOLERATE FROST

ECO WATER AS

Postboks 177, N-1430 Ås

Norway 

Tel: +47 454 26 200 

post@ecowater.no