10
ECOWATER
S Y S T E
M S
Programming the Digital Demand Faceplate Controller
4. SET RECHARGE (REGENERATION) TIME:
The controller is factory set to 2:00 AM. At this set-
ting, the EcoWater Systems conditioner begins re-
charge, or regeneration, ending no later than 5:30
AM. This is a good time in most households because
water is not being used. If
hot
water is used while the
unit is regenerating, the water heater will refill with
hard
water. To select a different recharge start time,
use the (
↑
) or (
↓
) keypad. Pressing the SELECT/
EXIT (
↵
) keypad will set the recharge time.
5. REMOTE SET--UP:
Press SELECT/EXIT (
↵
)
to enter the Primary Menu. Move the cursor next to
Advanced/Service Menu and press SELECT/EXIT
(
↵
) to enter this Menu. Warning screen will show.
Press (
↑
) keypad to continue. Move cursor to Test
Remote and press SELECT/EXIT (
↵
) to enter this
screen. The controller will start sending a signal to
the remote every 3 seconds. Press reset on the
back of remote. When the remote is receiving this
signal, the LED’s will flash red, amber, green. Now
remote can be placed in a convenient location. The
remote may not work in all places in your home. If
the red LED flashes twice every 3 seconds, the re-
mote is out of range of signal and needs to be re-
positioned. Press SELECT/EXIT (
↵
) to exit to the
Advanced/Service Menu. Move square cursor (
J
)
to EXIT and press SELECT/EXIT (
↵
). Now the unit
should start transmitting a normal signal.
GREEN LED
AMBER LED
RED LED
6.
Press the RECHARGE keypad to get to the re-
charge menu. Move the cursor to Start Recharge
Now and press the SELECT/EXIT (
↵
), starting a
recharge. This recharge
draws the bleach
(see
step 11, page 8) through the EcoWater Systems
conditioner
to sanitize
it and to purge any air re-
maining in the resin tank assembly.
7. RESTART THE WATER HEATER:
Turn on the electric or fuel supply to the water heater, and light
the pilot, if applies.
NOTE
: When the sanitizing regeneration is over, all remaining bleach is flushed from the conditioner and
your cold water supply is ready for use. However, the water heater is filled with HARD water and, as hot
water is used, it refills with conditioned water. In a few days, the hot water will be fully conditioned. To have
fully conditioned hot water immediately, wait until the recharge (step 6) is over. Then, drain the water heater
until water runs cold.
INSTALLATION OF THE DIGITAL DEMAND ECOWATER CONDITIONER IS COMPLETE.
Additional faceplate controller features and options are described on following pages.