Service Information
OTHER SERVICE
HARD WATER BYPASS
(hard water ‘‘bleeds’’ into
conditioned water supply).
1.
Defective inlet disc, seal, or wave washer (see pages
26 and 27).
2.
Missing or defective o--ring(s) at resin tank to valve con-
nection.
WATER LEAKS FROM DRAIN HOSE
(during ser-
vice).
1.
Defective inlet disc, seal, or wave washer.
2.
Defective o--ring on inlet disc shaft.
3.
Defective outlet disc, seal, or wave washer.
FLOODED SALT TANK
1.
Nozzle venturi plugged.
2.
Defective valve seals.
3.
Restricted or plugged backwash/fast rinse controls.
4.
Restricted or plugged drain line.
WATER HAS SALTY TASTE
1.
House water pressure low (adjust pump, if well system).
2.
Partially restricted valve drain hose, top distributor,
backwash flow plug, resin tank internal riser, or bottom
distributor.