Installation Requirements
PLUMBING CODES
All plumbing must be completed in accordance with
national, state and local plumbing codes.
VALVE DRAIN REQUIREMENTS
Using the flexible drain hose (included), measure and
cut to the length needed. Flexible drain hose is not
allowed in all localities (check your plumbing codes).
If local codes do not allow use of a flexible drain
hose, a rigid valve drain run must be used. Purchase
a compression fitting (1/2 NPT x 1/2 in. minimum
tube) and 1/2" tubing from your local hardware store.
Plumb a rigid drain as needed (see Figure 3, below).
NOTE:
Avoid drain hose runs longer that 30 feet.
Make the valve drain line as short and direct
as possible.
It is recommended that the Central Water Filtration
System be installed near a drain. However, if a drain
is not available, it is still possible to operate the
Central Water Filtration System in a manual Clean
Rinse mode. See “Operating in Manual Clean Rinse
Mode” section. The automatic Clean Rinse function
must be disabled if the Central Water Filtration
System will not be connected to a drain.
TYPICAL INSTALLATION
In the state of Massachusetts: The Commonwealth
of Massachusetts plumbing code 248-CMR shall
be adhered to. A licensed plumber shall be used
for this installation.
AIR GAP REQUIREMENTS
A drain is needed for Clean Rinse discharge water. A
floor drain, close to the Central Water Filtration
System, is preferred. A laundry tub, standpipe, etc.
are other drain options. Secure valve drain hose in
place. Leave an air gap of 1-1/2” between the end of
the hose and the drain. This gap is needed to pre-
vent backflow of sewer water into the Central Water
Filtration System . Do not put the end of the drain
hose into the drain.
FIG. 3
1-1/2”
air gap
Direct end of
hose down
toward center of
floor drain
Tie or wire
tubing in
place
LAUNDRY TUB
STANDPIPE
1-1/2”
air gap
FLOOR DRAIN
1-1/2”
air gap
To drain point other
than floor drain.
Support tubing in
place as needed.
Drain
Fitting
Clip
Barbs
1/2 NPT Threads
Comp Fitting. 1/2
NPT x 1/2” O.D.
Tube (not included)
Cut barbs from
drain fitting (pull
clip to remove
fitting from valve)
Hose
Clamp
Valve
Drain
Hose
1/2” Outside Dia.
Copper Tube
(not included)
SUBSTITUTING RIGID DRAIN LINE
120V, 60
Hz Outlet
To Electronic
Controller
Main Water Pipe
Filtered
Water
Incoming
Unfiltered
Water
To Outside
Faucets
IN
OUT