STANDPIPE
1--1/2”
airgap
drain
hose
1--1/2”
airgap
drain
hose
LAUNDRY TUB
DRAIN OPTIONS
4
FIG. 1B
ECOWATER
S Y S T E M S
Planning Installation
4 cm
airgap
4 cm
airgap
INLET / OUTLET PLUMBING OPTIONS
=
ALWAYS INSTALL either an EcoWater Systems bypass
valve #7214383, or a 3-valve bypass system. Bypass
valves allow you to turn off water to the conditioner/
refiner for repairs if needed, but still have water in
house pipes.
OTHER REQUIREMENTS
=
A drain is needed for recharge discharge water. A floor
drain is preferred, close to the EcoWater Systems
conditioner/refiner. A laundry tub, standpipe, etc., are
other options (See Figure 1B).
=
A 230V, 50 Hz, grounded, continuously “live” electrical
outlet is needed, in a dry location near the EcoWater
Systems conditioner/refiner.
FIG. 1
TYPICAL INSTALLATION ILLUSTRATIONS
4 cm
air gap
4 cm
air gap
230V, 50 Hz
electrical
outlet
floor drain
brine tank
overflow hose
(do not elevate)
valve drain hose
(do not elevate more
than 2.5 meters)
Tie or wire valve drain hose in place
to keep over floor drain
NOTE: Faceplate and support not
shown for clarity of drawing
EcoWater Systems
bypass valve
CABINET
MODEL
TWO-TANK
MODEL
floor drain
brine tank
overflow
hose
(do not
elevate)
INLET
OUTLET
OUTLET
INLET
transformer
(included)
power cord
to controller
(2 m long)
power cord
to controller
(2 m long)
HARD
WATER
HARD
WATER
CONDITIONED
WATER
MAIN WATER PIPE
MAIN WATER
PIPE
valve drain hose
(do not elevate more
than 2.5 meters)
EcoWater Systems
bypass valve