9
FIG. 16
MAIN MENU
Pressing the conditioner/refiner’s RIGHT (
4
) button
manually advances to the next screen in the sequence.
Pressing the LEFT (
3
) button manually returns to the
previous status screen. If no buttons are pressed for 30
seconds, the automatic rolling sequence resumes.
OTHER MESSAGES, ALERTS &
REMINDERS
The conditioner/refiner status screens described above
will not be displayed in a rolling sequence when one of
the following items is displayed:
=
Recharge status
(Displayed during recharges,
showing valve position and time remaining)
=
Add salt
or
Out of salt
(See Page 32)
=
Current time
setting screen instead of status
screens indicates time has been lost, perhaps after
a long power loss. Set the time (See Page 13).
=
Service reminder
(See Page 21)
=
Error detected
(Contact your dealer for service)
FLASHING BACKLIGHT
The conditioner/refiner’s display is backlit to make it
easy to read. The backlight will flash on and off when
one or more of the following conditions occurs:
=
Salt needs to be added
=
Time needs to be set (Time has been lost)
=
Service is overdue (Service reminder)
=
Error condition
The flashing will stop after any key is pressed.
However, it will start again at Midnight if the underlying
condition (e.g. low salt level) has not been addressed.
ECOWATER
S Y S T E M S
Conditioner/Refiner Operation
FIG. 15
*
*
Water remaining before the next recharge.
During normal operation (status screens rolling), press
the conditioner/refiner’s SELECT (
¡
) button to display
the Main menu (See Figure 16). This menu and its
subsidiary screens are used to control these operations:
=
Recharge
(See Page 13)
=
Salt settings
=
Salt level
(See Page 12)
=
Low salt alarm
(See Page 12)
=
Salt type
(See Page 12)
=
Basic settings
=
Current time
(See Page 13)
=
Hardness
(See Page 14)
=
Iron level
(See Page 14)
=
Recharge time
(See Page 14)
=
Rolling screens
(See Page 15)
=
User preferences
=
Language
(See Page 15)
=
Time format
(See Page 16)
=
Volume units
(See Page 16)
=
Hardness units
(See Page 16)
=
Weight units
(See Page 16)
=
System information
=
Model information
(See Page 17)
=
Water available
(See Page 17)
=
Daily avg. water used
(See Page 17)
=
Water used today
(See Page 17)
=
Total water used
(See Page 17)
=
Current water flow
(See Page 17)
=
Days powered up
(See Page 17)
=
Last recharge
(See Page 17)
=
Total recharges
(See Page 17)
=
Advanced settings
=
Cycle times
=
Backwash time
(See Page 18)
=
2nd backwash (On/Off)
(See Page 18)
=
2nd backwash time
(See Page 18)
=
Fast rinse time
(See Page 18)
=
Special features
=
Efficiency mode
(See Page 19)
=
Max. days between recharges
(See Page 19)
=
Auxiliary control
(See Page 20)
=
Chemical feed volume**
(See Page 20)
=
Chemical feed timer**
(See Page 20)
=
97% feature
(See Page 19)
=
Service reminder
(See Page 21)
=
Troubleshooting
=
Send E.A.S.E. message
(See Page 21)
=
Diagnostics
(See Page 22)
=
Setup changes
(See Page 22)
=
Connect to remote
(See Page 10)
**
Only displayed if Auxiliary control is set to Chemical feed.
CONDITIONER/REFINER STATUS SCREENS
During normal operation, the EcoWater Systems condi-
tioner/refiner’s display shows up to four status screens
(Page 15 explains how individual screens can be turned
on or off). Each is shown for six seconds, in a rolling
sequence (See Figure 15).