15
FIGURE 11
Line up when placing Hydrolink
Plus
®
RO Module under cover
Cover
Hydrolink Plus
®
RO Module
FIGURE 12
Route wire
as shown
Hydrolink Plus
®
RO Module
FIGURE 13
Feed wire through hanger opening
in rear panel of RO cabinet
Faucet
wire
Mount Hydrolink Plus
®
RO Module vertically
HYDROLINK PLUS
®
RO MODULE - WI-FI DATA / ALERTS
(HERO-385Plus Only)
POSITION HYDROLINK PLUS
®
RO MODULE UNDER RO COVER
(HERO-385Plus Only)
1.
Place the Hydrolink Plus
®
RO Module into the RO
manifold assembly, where shown in Figures 11 & 12.
Route the wire as shown in Figure 12 and carefully push
it down into the recesses on the manifold assembly while
holding the Hydrolink Plus
®
RO Module in place.
2.
Snap the cover onto the RO manifold assembly,
making sure that the Hydrolink Plus
®
RO Module is
lined up as shown in Figure 11.
If the Wi-Fi signal (strength displayed in the EASE
report) is weak, it may be necessary to mount the module
to the wall outside the RO cover (See Figure 13) There
is a recess on the back of the module for hanging it verti-
cally from a fastener (not included).
Once the Hydrolink Plus
®
RO module has been connect-
ed to the cloud and registered on the dealer’s web
account, a dashboard will be available to display data
items from the RO system:
DATA ITEMS
(updated daily between 2:00
&
2:59
AM
)
TDS Removal
Percentage
Total dissolved solids reduction
from inlet to outlet, as a percentage.
Filter Life Re -
maining (days)
Number of days before the filters
should be changed. It will be nega-
tive if filter change is overdue.
Dispensed
Gallons
Water dispensed through faucet
since last filter change, not includ-
ing water currently stored in tank.
Average Daily
Gallons
Daily average water use, in tenths of
a gallon.
ALERTS
(sent when triggered)
Replace
Batteries
Triggered when batteries are low (see
page 13 for replacement instructions)
Replace RO
Membrane
Triggered when TDS removal falls
below 75% (see pages 17 & 18 for
membrane replacement instructions)
Replace Filters
Triggered when filter life reaches
zero days (see page 17 for filter
replacement instructions)
RO System Not
Found
The Hydrolink Plus
®
module cannot
detect the RO manifold electronics
(the cable connection is shown in
Figure 7 on page 12)
To conserve battery life, the Hydrolink Plus
®
RO module
sends updates once a day, between 2:00 AM and 2:59 AM.
If a connection can’t be made (due to the internet being
down, for example), it will try again an hour later.
Click the ALERTS tab on the app to view any alerts.
Additional data items, such as number of days in opera-
tion and supply voltage, are shown in the EASE report.
Click the EASE tab on the app to view.