19
ECOWATER
S
Y
S
T
E
M
S
Service Information
RESIN BED CLEANING
If the water supply contains ‘‘clear water ’’ iron (see
page 13), regular resin bed cleaning is needed to
keep the bed from coating with iron. Use resin bed
cleaner, available from EcoWater, following direc-
tions on the container. Clean the resin every 6
months, or more often if iron appears in your condi-
tioned water supply.
ADDING RESIN
Normally, the resin bed (FIG. 14) will last the lifetime
of the EcoWater System Unit. However, certain
conditions may require partial or total replacement of
the resin bed. Some of these conditions are:
(1) damaged top and/or bottom distributors have al-
lowed resin to escape
(2) resin bed iron fouled beyond use
(3) some water supplies cause resin degradation
MODEL
NUMBER
RESIN TANK
SIZE
FREEBOARD
RANGE
LBS. RESIN PER
INCH BED DEPTH
ESD 525
10 x 35”
8” -- 10”
2.2
FREEBOARD
resin
bed
resin
tank
bottom
distributor
tube
add resin
plug distributor tube
while adding resin
Figure 14
IMPORTANT NOTES:
Turn off the water supply and relieve pressure...see
below.
Handle the resin tank carefully. It is heavy when filled
with resin and water.
Do not lose o--ring seals or other small parts.
Refer to the assembly instructions and to installation
steps to reassemble and restart the unit.
3 -- Valve Bypass
OUTLET
VALVE
INLET
VALVE
BYPASS
VALVE
water
flow
to conditioner
from conditioner
for
SERVICE:
-- Open
the
inlet
and
outlet valves.
-- Close
the
bypass valve.
for
BYPASS:
-- Close
the
inlet
and
outlet valves.
-- Open
the
bypass valve.
EcoWater Bypass Valve
CAUTION: ALWAYS relieve water pressure in the EcoWater System Unit,
as follows, before removing parts from the valve or resin tank.
DE--
PRESSURIZE
1.
Put bypass valve(s) in bypass position.
2.
Do Manual Advance step1, page 23, (fill water to brine tank will depressurize the resin
tank).
PRESSURIZE
1.
Put bypass valve(s) in service position.
2.
Do Manual Advance steps 2--5, page 23, to return unit to service.
ALTERNATE METHOD
3--VALVE BYPASS
ECOWATER BYPASS VALVE
DE--
PRESSURIZE
1.
Close the INLET valve.
2.
Open HOT and COLD conditioned water
house faucets.
3.
Close the OUTLET valve and open the
BYPASS valve.
4.
Close all house faucets.
PRESSURIZE
1.
Open HOT and COLD house faucets.
2.
Close the BYPASS valve and open the
OUTLET valve.
3. Slowly,
open the INLET valve.
4.
Close all house faucets
DE--
PRESSURIZE
1.
Close the house main water supply valve.
2.
Open HOT and COLD
conditioned
water
faucets.
3.
Push or rotate the bypass valve handle to
bypass position.
Note: For hard water bypass to house fau-
cets, reopen the main water supply valve.
PRESSURIZE
1.
Open HOT and COLD house faucets
(main water supply valve open).
2.
Pull or rotate the bypass valve handle to
service position.
3.