Assembly Instructions
TYPICAL INSTALLATION DRAWINGS
INLET -- OUTLET OPTIONS
1” copper tube
(2 supplied)
1’ x 1” strgt.
sweat connector
1’ x 3/4” strgt.
sweat connector
1” sweat x 1” or 3/4”
pipe thread
floor drain
floor drain
NOTE: Faceplate and support
not shown for clarity of drawing.
Tie or wire valve drain hose in place,
to keep over floor drain.
valve drain hose
valve drain hose
brine tank
overflow hose
brine tank
overflow hose
1--1/2”
airgap
120V, 60Hz
outlet
transformer
(supplied)
to timer
to timer
1--1/2”
airgap
INLET
INLET
OUTLET
OUTLET
3-- valve
bypass system
inlet
valve
outlet
valve
bypass
valve
HARD
WATER
HARD
WATER
CONDITIONED
WATER
Figure 2
INLET -- OUTLET PLUMBING OPTIONS
ALWAYS INSTALL either an EcoWater bypass
valve, #7129871, or a 3 valve bypass system. By-
pass valves allow you to turn off water to the soft-
ener for repairs if needed, but still have water in
house pipes.
Use 1”... or, 3/4” (minimum) pipe and fittings.
Use sweat copper... or, threaded pipe*... or, PVC
plastic pipe.*
*Sweat soldering is required to adapt to the fittings
(1” male) supplied with the EcoWater System Unit,
or obtain approved compression adaptors. The fol-
lowing special fittings are available from EcoWater.
Be sure to comply with all local plumbing codes.
OPTIONAL INLET/OUTLET FITTINGS
#7104546 PVC Nipple --- Use in place of
included copper inlet and outlet tubes.
#7129211 Adaptor Fitting, 1–1/2” (2) --- Use in
place of included copper inlet and outlet tubes.
#7120259 Elbow --- Extends inlet and/or outlet in
any 90° direction.