Typical Installation Illustrations
FIG. 6
Soft Water
OUT
INSTALLATION USING ECOWATER BYPASS VALVE
MAIN WATER PIP
E
Hard Water
IN
INSTALLATION USING 3-VALVE BYPASS
MAIN WATER PIP
E
BYPASS
Valve
OUTLET
Valve
INLET
Valve
For soft water SERVICE:
-Open the inlet and outlet
valves
For hard water BYPASS:
-Close the inlet and outlet
valves
-Open the bypass valve
CROSS-OVER
Use if water supply flows from the left.
Include single or 3-valve bypass.
HARD
WATER
TO SOFTENER
INLET
SOFT
WATER
FROM SOFTENER
OUTLET
Hard Water
to Outside
Faucets
EcoWater
Bypass Valve
CONNECTING A RIGID VALVE DRAIN TUBE
Compression Fitting.
1/4 NPT x 1/2” O.D.
Tube (not included)
Clip
Barbs
1/4 NPT
Threads
1/2” Outside Dia.
Copper Tube
(not included)
Cut barbs from drain fitting (pull
clip to remove fitting from valve)
120V,
60 Hz
Outlet
INLET
OUTLET
INLET
OUTLET
*Do not connect the water softener valve
drain hose to the brine tank overflow hose.
Valve Drain Hose
(do not elevate
more than 8 ft.)
Brine Tank Overflow
Hose* (optional) -
Install when a drain
is available below
level of elbow fitting.
Do not elevate hose.
to drain
- provide
a 1-1/2” minimum
air gap. Secure
the valve drain
hose in place to
keep over drain.