17
Service Information
ECOWATER
S Y S T E
M S
TO DRAIN
WARNING: FILTER
TANK CONTAINS AIR.
TO RELIEVE PRES-
SURE, PUT BYPASS
VALVE IN BYPASS AND
ADVANCE FILTER VALVE
TO BACKWASH BEFORE
DISASSEMBLY.
Adaptor Troubleshooting Guide
If excess air is in household plumbing, the
air vent is most likely plugged with debris.
Temporarily move the pump tube to the
drain fitting and energize the air pump.
After vent is cleared, change tubing back.
TROUBLESHOOTING
ALWAYS MAKE THESE
INITIAL CHECKS
FIRST
1. Does the time display show the correct time of
day?
...If display is blank, check power source to the filter.
...If time is flashing, power was off for over 6 hours.
The filter resumes normal operation but back-
washes occur at the wrong time.
2. Plumbing bypass valve(s) must be in SERVICE
position (see Figure 8, page 10).
3. The inlet and outlet pipes must connect to the filter
inlet and outlet respectively.
4. Is the transformer plugged into a “live” grounded
wall outlet, and the power cable fastened securely?
5. The valve drain hose must be free of kinks and
sharp bends.
6. If the air pump is not running, check for binding of
the turbine, check that the leads of the relay box are
connected to the back of the faceplate and there is
power to the relay box.
If you do not find the problem after making the initial
checks, do the MANUAL ADVANCE DIAGNOS-
TICS.