19
Service Information
ECOWATER
S Y S T E
M S
MANUAL ADVANCE DIAGNOSTIC
Use the following procedures to advance the filter
valve through the regeneration cycles to check op-
eration.
Remove the top cover to observe cam and switch
operation during valve rotation.
DISPLAY MUST SHOW TIME AND DAY
1. Press and hold the RECHARGE keypad for 3 sec-
onds until RECHARGE NOW flashes in the display
and the filter moves into the backwash cycle.
...If the motor does not run, check the motor and all
wiring connections.
Look for a fast flow of water from the drain hose (see
specifications, page 4).
...An obstructed flow indicates a plugged top distrib-
utor, backwash flow plug, or drain hose.
NOTE:
Be sure household water pressure (well sys-
tem) is maintained at a minimum of 20 psi. Adjust the
pump switch upward, if needed.
2. Press the RECHARGE keypad to move the filter
into fast rinse. Again, look for a drain flow rate about
the same as backwash.
3. To return the filter to service, press the RE-
CHARGE keypad once.
OTHER SERVICE
UNFILTERED WATER BYPASS (unfiltered water
“bleeds” into filtered water supply.
1. Missing or defective o--ring(s) at resin tank to
valve connection (see pages 20 and 21).
2. Defective rotor disc, seal or wave washer (see
pages 22 and 23).
WATER LEAKS FROM DRAIN HOSE (during ser-
vice)
1. Defective rotor disc, seal, or wave washer.
2. Defective o--ring on disc shaft.
AUTOMATIC ELECTRONIC DIAGNOSTICS
The face plate has a self diagnostic function for the
electrical systems (except input power). The face
plate monitors the electronic components and cir-
cuits for correct operation. If a malfunction occurs,
an error code appears in the face plate display.
POSSIBLE DEFECT
CODE
MOST LIKELY
³
----------------------------------------------------------------------------------------------
³
LEAST LIKELY
Err 01, Err 03
& Err 04
wiring harness or connection to position switch / switch / valve defect causing high torque / motor
inoperative
Err 05
faceplate
PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:
1. Unplug transformer-------- 2. Correct defect-------- 3.
Plug in transformer-------- 4. Wait for 12 minutes. The error code will return if the defect was not corrected. Press and hold the RECHARGE
keypad for 3 seconds as an alternate way to clear an error code.