Programming Face Plate Timer
ECOWATER
S Y S T E
M S
13
INFORMATION FOR QUALIFIED TECHNICIANS ONLY
RECHARGE CYCLE
TIME ADJUSTMENTS:
Factory set default cycle times are:
BACKWASH
...25 minutes, and
FAST RINSE
...5 minutes. Do the following to check for correct cycle times.
Note:
Removing from electrical power (about two
days) resets times to factory set defaults.
DISPLAY MUST SHOW TIME AND DAY
1. Press and
hold
SET ...
entire display comes on.
2. Press RECHARGE TIME
... 2:00 should show in the
display. If not, press SET
until 2:00 does show.
3. Press RECHARGE TIME
... 3:25 shows, meaning #3
cycle (backwash) and 25
minutes.
a. If 3:25
does
show, go to
step 4.
*b. If other than 3:25 (3:00 to
3:30), press SET until 3:25
shows.
4. Press RECHARGE TIME
... 4:05 shows, meaning #4
cycle (fast rinse) and 5 min-
utes.
a. If 4:05
does
show, go to
step 5.
b. If other than 4:05 (4:00 to
4:30), press SET until 4:05
shows.
5. Press RECHARGE TIME
... 18:88 shows.
6. Press SET to return present time and day.
*Or, set other cycle length, if desired.