27
ECOWATER
S Y S T E M S
Service Information
RELIEVING WATER PRESSURE WITH THE
BYPASS VALVE(S)
CAUTION: Always relieve water pressure in the
EcoWater Systems filter, as described below, before
removing parts from the valve or media tank.
DE-PRESSURIZE
1
. Put bypass valve(s) into
Bypass
position.
2
. Place filter valve in
Fill
position by performing Steps
1 & 5 of Manual Advance Recharge procedure on
Page 30.
PRESSURIZE
1
. Put bypass valve(s) into
Service
position.
2
. Return filter valve to
Service
position by performing
Steps 8 & 9 of Manual Advance Recharge procedure
on Page 30.
ALTERNATE METHODS:
3-VALVE BYPASS
(See Figure 91)
DE-PRESSURIZE
1
. Close the INLET valve.
2
. Open HOT and COLD conditioned water house
faucets.
3
. Close the OUTLET valve and open the BYPASS
valve.
4
. Close all house faucets.
PRESSURIZE
1
. Open HOT and COLD house faucets.
2
. Close the BYPASS valve and open the OUTLET
valve.
3
.
Slowly
, open the INLET valve.
4
. Close all house faucets.
ECOWATER SYSTEMS BYPASS VALVE
(See Figure 92)
DE-PRESSURIZE
1
. Close the house main water supply valve.
2
. Open HOT and COLD conditioned water house
faucets.
3
. Push the bypass valve handle to
Bypass
position.
4
. Optional: For unfiltered water bypass to house
faucets, reopen the main water supply valve.
PRESSURIZE
1
. Open main water supply valve if it is closed.
2
. Open HOT and COLD house faucets.
3
. Pull the bypass valve handle to
Service
position.
4
. Close all house faucets.
FIG. 92
FIG. 91
BYPASS
VALVE
EcoWater Systems Bypass Valve
3-Valve Bypass
To
Filter
From
Filter
Water Flo
w
OUTLET
VALVE
INLET
VALVE
For
Service
Close Bypass Valve.
Open Inlet & Outlet
Valves.
For
Bypass
Open Bypass Valve.
Close Inlet & Outlet
Valves.
Pull out for
Service
(Filtered water)
Push in for
Bypass