2
INSTRUCTIONS
eVOLUTION Series Water Conditioner / Refiner
English
SAFETY GUIDES
=
Before beginning installation, read the manual and obtain
tools and materials needed.
=
The installation must conform to local plumbing and
electrical codes.
=
Use only lead-free solder and flux for all sweat solder
connections.
=
Handle the conditioner/refiner with care. Do not turn upside
down, drop, or set on sharp protrusions.
=
Do not locate the conditioner/refiner:
-
where freezing temperatures may occur.
-
in direct sunlight.
-
where it may be exposed to wet weather.
=
Do not attempt to treat water over 49°C.
=
The conditioner/refiner requires a minimum water flow of 11
liters per minute at the inlet.
=
Maximum allowable inlet water pressure is 8.6 bar. If daytime
pressure is over 5.5 bar, nighttime pressure may exceed the
maximum. Use a pressure reducing valve if necessary.
=
This system works on 28 volt DC electrical power. Be sure to
use the included power supply and plug it into a nominal
220-240V, 50 Hz household outlet that is in a dry location
only, grounded and properly protected by an over current
device such as a circuit breaker or fuse.
=
This system is not intended to be used for treating water that
is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
European Directive 2002/96/EC requires all electrical
and electronic equipment to be disposed of according
to Waste Electrical and Electronic Equipment
(WEEE) requirements. This directive or similar laws
are in place nationally and can vary from region to
region. Please refer to your state and local laws for
proper disposal of the equipment.
INSTALLATION REQUIREMENTS
=
Installation should only be performed by a
trained professional.
=
Make sure that the main water supply is shut
off before starting installation.
=
Always install either an EcoWater Systems
bypass valve or a 3-valve bypass system.
Bypass valves allow you to turn off water to
the conditioner/refiner for repairs if needed,
but still have water in house pipes.
=
A drain is needed for recharge discharge
water. A floor drain is preferred, close to the
EcoWater Systems conditioner/refiner.
A laundry tub, standpipe, etc., are other
options.
=
A 220-240V, 50 Hz, grounded, continuously
“live” electrical outlet is needed, in a dry
location within 2 meters of the EcoWater
Systems conditioner/refiner.
=
After completing installation of the system,
perform a pressure test to detect any leaks.
=
After completing pressure test, perform a
manual recharge.
TABLE OF CONTENTS
Page
Installation Requirements . . . . . . . . . . . . 2
Safety Guides . . . . . . . . . . . . . . . . . . . . . 2
Installation Illustrations . . . . . . . . . . . . . . . 3
Conditioner/Refiner Programming . . . . 4-8
Adding Salt . . . . . . . . . . . . . . . . . . . . . . . . 9
Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . 9
EcoWater Systems Europe
=
www.ecowater-europe.com
A detailed manual can be obtained from your local dealer or from the EcoWater website in your country.
Models
eVOLUTION Compact 100, eVOLUTION Compact 200,
eVOLUTION Boost 300, eVOLUTION Boost 400,
eVOLUTION Power 500, eVOLUTION Power 600,
eVOLUTION Refiner Boost, eVOLUTION Refiner Power