Warning
installation and extraordinary maintenance must be done only by skilled, technical personnel.
• important notE
: if the stove is connected to the outside by a metal flue gas ex-
haust pipe, two conditions could be deleterious to good combustion.
1- if the horizontal part of the flue gas exhaust pipe is too long, this will worsen the quality
of combustion and noticeably increase ash residues in the grate. For this reason the
electronics board has a facility for regulating both the exhaust pressure and pellet loading
rate. this should be carried out only by the installer technician, at installation or when
conditions make it necessary.
2- A vertical metal exhaust pipe that is three / four metres long will increase the combus-
tion rate. this will cause the stove to go out at the minimum power level. to prevent this
just increase the selected power level or change the original settings.
MAINTENANCE OF THE SMOKE ExHAUST DUCT
• Annually, we recommend cleaning the smoke exhaust duct in order to prevent self-
combustion of any soot and powder that may be deposited there.
• in case of fire switch off the stove immediately and disconnect it from the power supply.