Pretty - Nice - LADy
UK
6
instaLLation
the stove must be installed by qualified personnel, who must diligently follow all
the rules for correct installation, respecting all the relevant technical, legal and
safety standards in force at the time.
When positioning the stove respect the
distances shown in the drawing on the
right.
Place the stove away from curtains, fabrics,
ornaments or anything else that may
cause fire.
if the stove is positioned near a wood-lined wall or the gas exhaust pipe is in contact with
similar material, insulate the material with suitable fireproof or fire-resistant products.
connect the flue pipe of your stove to an existing
chimney or, alternatively, install a fume exhaust
pipe outside the building. the pipe must have a
minimum pipe diameter of 80 mm and reach
higher than the top of the roof.
if the stove is installed in a building with poten-
tially inflammable walls, it will be necessary to
place an insulating sleeve between the wall and
the flue gas exhaust pipe and similarly for the
overhanging part of the building’s roof.
A t-pipe for inspection should always be installed
between the flue gas outlet on the stove and the
flue itself.
insulating sleeve
insulating sleeve
combustion air inlet
rain protection cover